Evaluation of Methods for Characterizing Kilovoltage Beam Quality from the Varian TrueBeam STx

Purpose: This study evaluated various methods for determining the half-value layer (HVL) of kilovoltage (kV) beams produced by the Varian TrueBeam STx on-board imager.By comparing these methods with the standard ionization chamber approach, the study aimed to identify practical solutions for HVL determination and dosimetric characterization of kV beams, particularly in resource-limited settings.Methods: HVLs for kV beams (40-140 kVp) were measured using an Exradin A12 ionization chamber and a Piranha MULTI meter.The ionization chamber measurements adhered to American Association of Physicists in Medicine Task Group 61 guidelines and served as the reference standard.Additionally, HVL values were calculated using two model-based approaches: SpekPy (a Python-based tool) and Monte Carlo (MC) simulations using Geant4 and GATE.The results from these methods were compared to assess consistency and reliability.Results: Deviations across all methods were generally below 4%.At 40 kV, the most significant discrepancies were attributed to lower signal levels from the ionization chamber.The consistency between the model-based methods and experimental measurements demonstrates the reliability of these alternative approaches for HVL determination.Conclusions: Although the ionization chamber remains the gold standard, the Piranha MULTI meter and model-based methods, i.e., SpekPy and MC simulations, have shown promise as viable alternatives, especially in resource-constrained settings.These in silico approaches also offer advantages in convenience and accuracy, supporting their potential for broader future applications.

Authors

Institutions

Publication Details

Journal
Progress in Medical Physics
Published
2024-12-31
DOI
https://doi.org/10.14316/pmp.2024.35.4.98
Primary Topic
Engineering Applied Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Methods for Characterizing Kilovoltage Beam Quality from the Varian TrueBeam STx

Inbum Lee, Jung‐in Kim, Seonghee Kang, Jin Jegal et al.
Progress in Medical Physics
Engineering Applied Research
article

Evaluation of Methods for Characterizing Kilovoltage Beam Quality from the Varian TrueBeam STx

Inbum Lee, Jung‐in Kim, Seonghee Kang, Jin Jegal, Hyojun Park, Yoonsuk Huh, Chang Heon Choi
article en

Abstract

Purpose: This study evaluated various methods for determining the half-value layer (HVL) of kilovoltage (kV) beams produced by the Varian TrueBeam STx on-board imager.By comparing these methods with the standard ionization chamber approach, the study aimed to identify practical solutions for HVL determination and dosimetric characterization of kV beams, particularly in resource-limited settings.Methods: HVLs for kV beams (40-140 kVp) were measured using an Exradin A12 ionization chamber and a Piranha MULTI meter.The ionization chamber measurements adhered to American Association of Physicists in Medicine Task Group 61 guidelines and served as the reference standard.Additionally, HVL values were calculated using two model-based approaches: SpekPy (a Python-based tool) and Monte Carlo (MC) simulations using Geant4 and GATE.The results from these methods were compared to assess consistency and reliability.Results: Deviations across all methods were generally below 4%.At 40 kV, the most significant discrepancies were attributed to lower signal levels from the ionization chamber.The consistency between the model-based methods and experimental measurements demonstrates the reliability of these alternative approaches for HVL determination.Conclusions: Although the ionization chamber remains the gold standard, the Piranha MULTI meter and model-based methods, i.e., SpekPy and MC simulations, have shown promise as viable alternatives, especially in resource-constrained settings.These in silico approaches also offer advantages in convenience and accuracy, supporting their potential for broader future applications.

Progress in Medical PhysicsVol. 35(4)
Seoul National University (KR), Seoul National University Hospital (KR)
Ministry of Trade, Industry and Energy, Korea Institute of Energy Technology Evaluation and Planning
Affordable and clean energy
Openalex Percentile: Top 71%
Engineering Applied Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.