Quantitative Assessment in Dynamic PET/CT for Hepatocellular Carcinoma through Bayesian Prior information-based Actor-Critic algorithm

Dynamic positron emission tomography/computed tomography (PET/CT) is a promising medical imaging technique that enables the visualization of biological processes via tracer activity. Analyzing the time-activity curves (TACs) of PET using pharmacokinetic models allows for the extraction of quantifiable physiological information relevant to hepatocellular carcinoma (HCC). Estimation of the pharmacokinetic model parameters requires advanced algorithms. The challenge lies in achieving accurate parameter estimation and obtaining parameter distributions that align with physiological characteristics. This paper introduces a reinforcement learning-based Actor-Critic (AC) algorithm and proposes a Bayesian prior information-based Actor-Critic (BPAC) algorithm. A dynamic parameter estimation environment for agent interaction was established, incorporating Bayesian optimization. The preceding information obtained through Bayesian optimization was used to design the reward and penalty signals in the interaction environment, and sampled as the initial value for the agent to estimate the parameters of 24 real HCC cases. Receiver operating characteristic (ROC) analyses were performed, using P-values and areas under the curve (AUC) to evaluate diagnostic performance between normal and tumor groups. Compared to the AC, the BPAC demonstrates statistically significant differences in K1, k2, k3, fa, and vb (all P < 0.001) and aligns more closely with correct physiological characteristics in K1, k2, k3, k4, and fa. In ROC analyses, five parameters derived from the proposed method achieved higher AUC values than the AC. Results indicate that BPAC can more effectively quantitatively evaluate the physiological characteristics of HCC, such as perfusion and metabolism, resulting in superior diagnostic performance.

Authors

Institutions

Publication Details

Published
2024-10-25
DOI
https://doi.org/10.1145/3704323.3704368
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantitative Assessment in Dynamic PET/CT for Hepatocellular Carcinoma through Bayesian Prior information-based Actor-Critic algorithm

Siming Li, Shaobo Wang, Jingchun Huang, Jia He
Medical Imaging Techniques and Applications
article

Quantitative Assessment in Dynamic PET/CT for Hepatocellular Carcinoma through Bayesian Prior information-based Actor-Critic algorithm

Siming Li, Shaobo Wang, Jingchun Huang, Jia He
article en

Abstract

Dynamic positron emission tomography/computed tomography (PET/CT) is a promising medical imaging technique that enables the visualization of biological processes via tracer activity. Analyzing the time-activity curves (TACs) of PET using pharmacokinetic models allows for the extraction of quantifiable physiological information relevant to hepatocellular carcinoma (HCC). Estimation of the pharmacokinetic model parameters requires advanced algorithms. The challenge lies in achieving accurate parameter estimation and obtaining parameter distributions that align with physiological characteristics. This paper introduces a reinforcement learning-based Actor-Critic (AC) algorithm and proposes a Bayesian prior information-based Actor-Critic (BPAC) algorithm. A dynamic parameter estimation environment for agent interaction was established, incorporating Bayesian optimization. The preceding information obtained through Bayesian optimization was used to design the reward and penalty signals in the interaction environment, and sampled as the initial value for the agent to estimate the parameters of 24 real HCC cases. Receiver operating characteristic (ROC) analyses were performed, using P-values and areas under the curve (AUC) to evaluate diagnostic performance between normal and tumor groups. Compared to the AC, the BPAC demonstrates statistically significant differences in K1, k2, k3, fa, and vb (all P < 0.001) and aligns more closely with correct physiological characteristics in K1, k2, k3, k4, and fa. In ROC analyses, five parameters derived from the proposed method achieved higher AUC values than the AC. Results indicate that BPAC can more effectively quantitatively evaluate the physiological characteristics of HCC, such as perfusion and metabolism, resulting in superior diagnostic performance.

Kunming University of Science and Technology (CN)
Openalex Percentile: Top 58%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.