Stability Domain Construction and Tuning for External Loop Controller Parameters Based on Permanent Magnet Wind Power Generation Systems

Based on the closed‐loop frequency domain model of permanent magnet synchronous generator–based wind power generation system (PMSG‐WPGS), the stability domain of the control parameters is constructed through the D‐partition method in this paper to acquire the range of machine‐side converter (MSC) and grid‐side converter (GSC) parameters. First, the basic stability domain of the controller parameters is established according to the control structure and transfer function of the back‐to‐back converter. Then, based on the frequency domain performance indexes, amplitude margin and phase angle margin, the obtained basic stability domain is adjusted to further gain the control parameter values that meet the frequency domain index. Furthermore, the rationality of the stability domain range is verified by drawing root locus curves of variable controller parameters on the machine side and grid side. Finally, the low‐power scale experimental platform of PMSG‐WPGS is built in the lab to validate the feasibility of the proposed stability domain construction method.

Authors

Institutions

Publication Details

Journal
International Transactions on Electrical Energy Systems
Published
2025-01-01
DOI
https://doi.org/10.1155/etep/5538585
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Stability Domain Construction and Tuning for External Loop Controller Parameters Based on Permanent Magnet Wind Power Generation Systems

Chuan Qin, Guangtao Zhang, Fei He, Hao Liang
International Transactions on Electrical Energy Systems
Microgrid Control and Optimization
article

Stability Domain Construction and Tuning for External Loop Controller Parameters Based on Permanent Magnet Wind Power Generation Systems

Chuan Qin, Guangtao Zhang, Fei He, Hao Liang
article en

Abstract

Based on the closed‐loop frequency domain model of permanent magnet synchronous generator–based wind power generation system (PMSG‐WPGS), the stability domain of the control parameters is constructed through the D‐partition method in this paper to acquire the range of machine‐side converter (MSC) and grid‐side converter (GSC) parameters. First, the basic stability domain of the controller parameters is established according to the control structure and transfer function of the back‐to‐back converter. Then, based on the frequency domain performance indexes, amplitude margin and phase angle margin, the obtained basic stability domain is adjusted to further gain the control parameter values that meet the frequency domain index. Furthermore, the rationality of the stability domain range is verified by drawing root locus curves of variable controller parameters on the machine side and grid side. Finally, the low‐power scale experimental platform of PMSG‐WPGS is built in the lab to validate the feasibility of the proposed stability domain construction method.

International Transactions on Electrical Energy SystemsVol. 2025(1)
Hohai University (CN)
State Grid Corporation of China
Affordable and clean energy
Openalex Percentile: Top 100%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Stability Domain Construction and Tuning for External Loop Controller Parameters Based on Permanent Magnet Wind Power Generation Systems — Chuan Qin, Guangtao Zhang, et al. · International Transactions on Electrical Energy Systems (2025) | TGRS Research Map | TGRS