Innovative RP-HPLC Technique for Method Development and Validation of Propylthiouracil Tablets

This work focuses on the use of high-performance liquid chromatography (HPLC) for the quantitative analysis and validation of propylthiouracil tablets through reverse phase chromatography (HPLC- RP). The analysis was optimised using a C18 column with a mobile phase that includes acetonitrile and buffer in a ratio of 20:80 (v/v). The buffer is made from monobasic potassium phosphate with a pH of 4.6 ± 0.05. The detection of propylthiouracil was performed at λ = 272 nm. Samples were extracted using methanol and water. The newly developed method exhibited good linearity between 24.916 and 74.748 µg/mL, with an R2 > 0.999. Precision expressed in terms of % relative standard deviation (RSD) was within the acceptable range, whereas accuracy in terms of % recovery varied between 98-102%. Therefore, the proposed and validated HPLC-RP method is reliable for the quantitative analysis of propylthiouracil in pharmaceutical formulations, ensuring accurate dosage determination and quality control. The technique shows promising potential for pharmacokinetic studies and routine quality assurance in the pharmaceutical industry.

Authors

Institutions

Publication Details

Journal
Biomedical & Pharmacology Journal
Published
2024-12-30
DOI
https://doi.org/10.13005/bpj/3047
Primary Topic
Analytical Chemistry and Chromatography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Innovative RP-HPLC Technique for Method Development and Validation of Propylthiouracil Tablets

P. Muthukumar, Umamaheswari Duraisamy
Biomedical & Pharmacology Journal
Analytical Chemistry and Chromatography
article

Innovative RP-HPLC Technique for Method Development and Validation of Propylthiouracil Tablets

P. Muthukumar, Umamaheswari Duraisamy
article en

Abstract

This work focuses on the use of high-performance liquid chromatography (HPLC) for the quantitative analysis and validation of propylthiouracil tablets through reverse phase chromatography (HPLC- RP). The analysis was optimised using a C18 column with a mobile phase that includes acetonitrile and buffer in a ratio of 20:80 (v/v). The buffer is made from monobasic potassium phosphate with a pH of 4.6 ± 0.05. The detection of propylthiouracil was performed at λ = 272 nm. Samples were extracted using methanol and water. The newly developed method exhibited good linearity between 24.916 and 74.748 µg/mL, with an R2 > 0.999. Precision expressed in terms of % relative standard deviation (RSD) was within the acceptable range, whereas accuracy in terms of % recovery varied between 98-102%. Therefore, the proposed and validated HPLC-RP method is reliable for the quantitative analysis of propylthiouracil in pharmaceutical formulations, ensuring accurate dosage determination and quality control. The technique shows promising potential for pharmacokinetic studies and routine quality assurance in the pharmaceutical industry.

Biomedical & Pharmacology JournalVol. 17(4)
Vinayaka Missions University (IN)
Industry, innovation and infrastructure
Openalex Percentile: Top 81%
Analytical Chemistry and Chromatography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.