Biomechanical evaluation of conventional locking compression plate and double locking compression plate combined with locking screw use to stabilize midshaft ulna fracture: A finite element study

This study explored the impact of midshaft ulna fractures on biomechanical performance of double locking compression (D-LCP) in comparison to conventional locking compression plates, utilizing finite element method. The study included transverse middle fractures stabilized with titanium implants, involving models of midshaft ulna and two fixation plates (D-LCP implant and C-LCP implant) created and aligned virtually using CAD. Four-node tetrahedral elements were employed in the finite element model, and regular daily activity loading conditions were applied to each model at axial compression, axial torsion, and lateral bending. EQV stress was observed around the distal screw contact in both C-LCP and D-LCP models, with D-LCP exhibiting lower EQV stress than C-LCP, particularly under axial compression. The D-LCP cases demonstrated less bone fracture displacement compared to C-LCP cases, providing valuable insights. Additionally, the bone stress in D-LCP revealed significantly lower levels compared to C-LCP.

Authors

Institutions

Publication Details

Journal
Science, Engineering and Health Studies
Published
2024-12-29
DOI
https://doi.org/10.69598/sehs.18.24040007
Primary Topic
Bone fractures and treatments
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biomechanical evaluation of conventional locking compression plate and double locking compression plate combined with locking screw use to stabilize midshaft ulna fracture: A finite element study

Nattapon Chantarapanich, Sujin Wanchat, Potsadom Moraksa
Science, Engineering and Health Studies
Bone fractures and treatments
article

Biomechanical evaluation of conventional locking compression plate and double locking compression plate combined with locking screw use to stabilize midshaft ulna fracture: A finite element study

Nattapon Chantarapanich, Sujin Wanchat, Potsadom Moraksa
article en

Abstract

This study explored the impact of midshaft ulna fractures on biomechanical performance of double locking compression (D-LCP) in comparison to conventional locking compression plates, utilizing finite element method. The study included transverse middle fractures stabilized with titanium implants, involving models of midshaft ulna and two fixation plates (D-LCP implant and C-LCP implant) created and aligned virtually using CAD. Four-node tetrahedral elements were employed in the finite element model, and regular daily activity loading conditions were applied to each model at axial compression, axial torsion, and lateral bending. EQV stress was observed around the distal screw contact in both C-LCP and D-LCP models, with D-LCP exhibiting lower EQV stress than C-LCP, particularly under axial compression. The D-LCP cases demonstrated less bone fracture displacement compared to C-LCP cases, providing valuable insights. Additionally, the bone stress in D-LCP revealed significantly lower levels compared to C-LCP.

Science, Engineering and Health Studies
Kasetsart University (TH)
Kasetsart University
Openalex Percentile: Top 63%
Bone fractures and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.