In Vitro Evaluation of the Effect of Scanning Strategy on the Accuracy of Intraoral Scanners

Background: The accuracy of intraoral scanners depends on the scanning strategy, but evidence on how these strategies affect trueness and precision across scanners is limited. Identifying optimal strategies is key to improving performance and clinical outcomes. Materials and Methods: A dental cast obtained from an impression of a fully-dentate patient was initially scanned by a laboratory scanner and then by three intraoral scanners namely Trios®4, Carestream 3800, and Medit i700 with three different scanning strategies of A (occlusal surfaces from the left end to the right end, followed by lingual and then buccal surfaces), B (buccal surfaces followed by occlusal and then lingual surfaces from left to right), and C (continuous labiolingual movement with left-to-right direction). Scans were converted to STL format and analyzed in Geomagic for trueness and precision (ISO 5725-1) using ANOVA, Tukey, Welch, and Games-Howell tests (alpha = 0.05). Results: The effect of scanning strategy was significant on trueness of Carestream (P=0.002) but not Medit and Trios4 (P>0.05). In Carestream, the trueness of strategy A was significantly higher than B (P=0.001). The effect of scanning strategy was significant on precision of Medit (P<0.001) but not Carestream and Trios4 (P>0.05). In Medit, the precision of strategy B was significantly lower than A and C (P<0.001 for both). Conclusion: The scanning strategy's effect on accuracy varied by scanner type. Strategy A was most accurate in Carestream, while strategy B showed the lowest precision in Medit i700. Other scanners and strategies had similar precision.

Authors

Institutions

Publication Details

Journal
Galen Medical Journal
Published
2024-12-30
DOI
https://doi.org/10.31661/gmj.v13isp1.3748
Citations
1
Primary Topic
Advanced Measurement and Metrology Techniques
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In Vitro Evaluation of the Effect of Scanning Strategy on the Accuracy of Intraoral Scanners

Mitra Eisaei, S.Shojaeddin Shayegh, Mohammad Amin Bafandeh, Mohammad Ghadirifard et al.
1 citations
Galen Medical Journal
Advanced Measurement and Metrology Techniques
0.21
article

In Vitro Evaluation of the Effect of Scanning Strategy on the Accuracy of Intraoral Scanners

Mitra Eisaei, S.Shojaeddin Shayegh, Mohammad Amin Bafandeh, Mohammad Ghadirifard, Sayed Mohammadreza Hakimaneh
article en
1 citations

Abstract

Background: The accuracy of intraoral scanners depends on the scanning strategy, but evidence on how these strategies affect trueness and precision across scanners is limited. Identifying optimal strategies is key to improving performance and clinical outcomes. Materials and Methods: A dental cast obtained from an impression of a fully-dentate patient was initially scanned by a laboratory scanner and then by three intraoral scanners namely Trios®4, Carestream 3800, and Medit i700 with three different scanning strategies of A (occlusal surfaces from the left end to the right end, followed by lingual and then buccal surfaces), B (buccal surfaces followed by occlusal and then lingual surfaces from left to right), and C (continuous labiolingual movement with left-to-right direction). Scans were converted to STL format and analyzed in Geomagic for trueness and precision (ISO 5725-1) using ANOVA, Tukey, Welch, and Games-Howell tests (alpha = 0.05). Results: The effect of scanning strategy was significant on trueness of Carestream (P=0.002) but not Medit and Trios4 (P>0.05). In Carestream, the trueness of strategy A was significantly higher than B (P=0.001). The effect of scanning strategy was significant on precision of Medit (P<0.001) but not Carestream and Trios4 (P>0.05). In Medit, the precision of strategy B was significantly lower than A and C (P<0.001 for both). Conclusion: The scanning strategy's effect on accuracy varied by scanner type. Strategy A was most accurate in Carestream, while strategy B showed the lowest precision in Medit i700. Other scanners and strategies had similar precision.

Galen Medical JournalVol. 13(SP1)
Shahed University (IR)
Openalex Percentile: Top 48%
Advanced Measurement and Metrology Techniques
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

In Vitro Evaluation of the Effect of Scanning Strategy on the Accuracy of Intraoral Scanners — Mitra Eisaei, S.Shojaeddin Shayegh, et al. · Galen Medical Journal (2024) | TGRS Research Map | TGRS