Development and Performance Analysis of Indoor PM2.5 Preemptive Control Algorithm

Purpose: Recently, as the demand for comfortable indoor environments has significantly increased, the importance of the health of occupants has come to the forefront. In response to this societal issue, this study developed an integrated control algorithm for ventilation and air purification system that can proactively manage indoor PMsub 2.5/sub levels. Method: To analyze the performance of the developed indoor PMsub2.5/sub preemptive control algorithm, ventilation and air purification systems installed in two actively used elementary school classrooms were utilized. The control algorithm incorporates an ANN based indoor PM sub2.5/sub prediction model and derives control values using the predicted values and real-time environmental data. Data obtained through empirical studies were analyzed according to occupancy schedules to verify compliance with national recommended standards. Additionally, an analysis of the control algorithm's inherent performance was conducted. Result: The preemptive control algorithm was observed to maintain lower indoor PMsub 2.5/sub concentrations and sustain the comfortable range for extended periods compared to rule based control algorithms. However, the system operating time was longer than that of rule based control algorithms.

Authors

Publication Details

Journal
KIEAE Journal
Published
2024-12-31
DOI
https://doi.org/10.12813/kieae.2024.24.6.047
Primary Topic
Air Quality Monitoring and Forecasting
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Performance Analysis of Indoor PM2.5 Preemptive Control Algorithm

Jung-Hyung Lee, Tae-Won Kim
KIEAE Journal
Air Quality Monitoring and Forecasting
article

Development and Performance Analysis of Indoor PM2.5 Preemptive Control Algorithm

Jung-Hyung Lee, Tae-Won Kim
article en

Abstract

Purpose: Recently, as the demand for comfortable indoor environments has significantly increased, the importance of the health of occupants has come to the forefront. In response to this societal issue, this study developed an integrated control algorithm for ventilation and air purification system that can proactively manage indoor PMsub 2.5/sub levels. Method: To analyze the performance of the developed indoor PMsub2.5/sub preemptive control algorithm, ventilation and air purification systems installed in two actively used elementary school classrooms were utilized. The control algorithm incorporates an ANN based indoor PM sub2.5/sub prediction model and derives control values using the predicted values and real-time environmental data. Data obtained through empirical studies were analyzed according to occupancy schedules to verify compliance with national recommended standards. Additionally, an analysis of the control algorithm's inherent performance was conducted. Result: The preemptive control algorithm was observed to maintain lower indoor PMsub 2.5/sub concentrations and sustain the comfortable range for extended periods compared to rule based control algorithms. However, the system operating time was longer than that of rule based control algorithms.

KIEAE JournalVol. 24(6)
Chung-Ang University
Industry, innovation and infrastructure
Openalex Percentile: Top 78%
Air Quality Monitoring and Forecasting
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Development and Performance Analysis of Indoor PM2.5 Preemptive Control Algorithm — Jung-Hyung Lee, Tae-Won Kim · KIEAE Journal (2024) | TGRS Research Map | TGRS