Carbon Paste Electrode Modified Zeolite-Iron as a Chromium(VI) Detection Medium

Chromium exists in two dominant species in nature, Cr(III) and Cr(VI). Both are stable; however, Cr(VI) exhibits significantly higher toxicity than Cr(III). Existing measurement methods could not differentiate between these two chromium species. Therefore, a more sensitive and selective measurement method was required for their speciation, particularly for Cr(VI) detection. In this study, a carbon paste electrode modified with zeolite and iron was developed for Cr(VI) measurement using the voltammetry method. The electrode was prepared by mixing graphite, iron-modified zeolite, and liquid paraffin. Measurements were conducted using cyclic voltammetry within a potential range of -1.2 V to 1.2 V. A 0.05 M KCl solution was used as the electrolyte. Electrode characterization was carried out concerning three parameters: the effect of analyte pH, preconcentration time, and the composition of iron-modified zeolite. The optimum Cr(VI) measurement was achieved in a 50 μM Cr(VI) solution at pH 3 using a carbon paste electrode with 20% iron-modified zeolite and a preconcentration time of 25 min. Under these optimal conditions, a cathodic peak current of 5.22 μA was obtained.

Authors

Institutions

Publication Details

Journal
Indonesian Journal of Chemical Studies
Published
2024-12-31
DOI
https://doi.org/10.55749/ijcs.v3i2.64
Primary Topic
Electrochemical Analysis and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Carbon Paste Electrode Modified Zeolite-Iron as a Chromium(VI) Detection Medium

Eti Rohaeti, Rofiqoh Inayati Agustina, Nur Aini, Zulhan Arif et al.
Indonesian Journal of Chemical Studies
Electrochemical Analysis and Applications
article

Carbon Paste Electrode Modified Zeolite-Iron as a Chromium(VI) Detection Medium

Eti Rohaeti, Rofiqoh Inayati Agustina, Nur Aini, Zulhan Arif, Heni Rahmawati
article en

Abstract

Chromium exists in two dominant species in nature, Cr(III) and Cr(VI). Both are stable; however, Cr(VI) exhibits significantly higher toxicity than Cr(III). Existing measurement methods could not differentiate between these two chromium species. Therefore, a more sensitive and selective measurement method was required for their speciation, particularly for Cr(VI) detection. In this study, a carbon paste electrode modified with zeolite and iron was developed for Cr(VI) measurement using the voltammetry method. The electrode was prepared by mixing graphite, iron-modified zeolite, and liquid paraffin. Measurements were conducted using cyclic voltammetry within a potential range of -1.2 V to 1.2 V. A 0.05 M KCl solution was used as the electrolyte. Electrode characterization was carried out concerning three parameters: the effect of analyte pH, preconcentration time, and the composition of iron-modified zeolite. The optimum Cr(VI) measurement was achieved in a 50 μM Cr(VI) solution at pH 3 using a carbon paste electrode with 20% iron-modified zeolite and a preconcentration time of 25 min. Under these optimal conditions, a cathodic peak current of 5.22 μA was obtained.

Indonesian Journal of Chemical StudiesVol. 3(2)
IPB University (ID)
Openalex Percentile: Top 76%
Electrochemical Analysis and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Carbon Paste Electrode Modified Zeolite-Iron as a Chromium(VI) Detection Medium — Eti Rohaeti, Rofiqoh Inayati Agustina, et al. · Indonesian Journal of Chemical Studies (2024) | TGRS Research Map | TGRS