Analisis Kerusakan pada Rotor Pompa Sentrifugal G-1-12-C di PT X

Damage to a tool can cause the production process to stop and cause downtime. Preventing damage to equipment is by managing the maintenance process. This process includes preventive maintenance, corrective maintenance and predictions of damage (predictive maintenance) which is carried out periodically. Centrifugal pumps have the working principle of converting kinetic energy (speed) of liquid into potential (dynamic) energy through an impeller that rotates in the casing. This pump is an impeller that is mounted on a shaft with bearings at both ends. Damage to the pump rotor has a serious impact on the performance and reliability of the pump system. The rotor is one of the main components responsible for transferring mechanical energy into the pumped fluid, so damage to the rotor can affect pump efficiency, operational life, and damage to pump components. Analysis of damage to the pump rotor was carried out by testing using the NDT method. NDT testing includes Visual Inspection, Magnetic Particle Inspection, Liquid Penetrant and Balancing Rotor. Based on the results of the tests and analysis carried out, it was found that there was damage to several parts of the pump rotor, such as corrosion on the pump shaft, dirt on the surface, and scratches on the mechanical seal seat area with a depth of approximately 0.50 mm. Rotor unbalance or the center of gravity of the shaft rotation is not the same as the geometric center of the shaft. The impeller was found to be in poor condition, high metal of radial impeller and medium to heavy rubbing at wearing impeller. The DE and NDE distance sleeves are not in a bad condition and there are scratches.

Authors

Institutions

Publication Details

Journal
Jurnal Surya Teknika
Published
2024-12-31
DOI
https://doi.org/10.37859/jst.v11i2.8300
Primary Topic
Management and Optimization Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analisis Kerusakan pada Rotor Pompa Sentrifugal G-1-12-C di PT X

Alvera Apridalianti Melkias, Indriyani Indriyani, Fachry Fadian
Jurnal Surya Teknika
Management and Optimization Techniques
article

Analisis Kerusakan pada Rotor Pompa Sentrifugal G-1-12-C di PT X

Alvera Apridalianti Melkias, Indriyani Indriyani, Fachry Fadian
article en

Abstract

Damage to a tool can cause the production process to stop and cause downtime. Preventing damage to equipment is by managing the maintenance process. This process includes preventive maintenance, corrective maintenance and predictions of damage (predictive maintenance) which is carried out periodically. Centrifugal pumps have the working principle of converting kinetic energy (speed) of liquid into potential (dynamic) energy through an impeller that rotates in the casing. This pump is an impeller that is mounted on a shaft with bearings at both ends. Damage to the pump rotor has a serious impact on the performance and reliability of the pump system. The rotor is one of the main components responsible for transferring mechanical energy into the pumped fluid, so damage to the rotor can affect pump efficiency, operational life, and damage to pump components. Analysis of damage to the pump rotor was carried out by testing using the NDT method. NDT testing includes Visual Inspection, Magnetic Particle Inspection, Liquid Penetrant and Balancing Rotor. Based on the results of the tests and analysis carried out, it was found that there was damage to several parts of the pump rotor, such as corrosion on the pump shaft, dirt on the surface, and scratches on the mechanical seal seat area with a depth of approximately 0.50 mm. Rotor unbalance or the center of gravity of the shaft rotation is not the same as the geometric center of the shaft. The impeller was found to be in poor condition, high metal of radial impeller and medium to heavy rubbing at wearing impeller. The DE and NDE distance sleeves are not in a bad condition and there are scratches.

Jurnal Surya TeknikaVol. 11(2)
Bandung Institute of Technology (ID), Politeknik Negeri Bandung
Affordable and clean energy
Openalex Percentile: Top 57%
Management and Optimization Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.