Experiment of PI Controller for Indirect Current Control for Single – Phase Shunt Active Filter

Due to harmonic problems caused by various factors that resulted in damages and malfunctions of electrical equipment in the power system, eliminating harmonics in the electrical system has become an important issue for both industrial and household sectors. This article focuses on developing a current control method for a single-phase shunt active power filter (APF) that controls current by an indirect method. The detection of load current to generate reference signals uses the dq-axis reference frame for a single-phase electrical system. The design of circuit parameters and PI controller parameters for compensating current and DC bus voltage are based on a simple calculation method. Simulation and experimental results confirm that the proposed current control method and PI controller design effectively eliminate harmonics, with the percent of total current harmonic distortion (THDi) values of the supply current after compensation within the IEEE Std 519-2022 standard limit.

Authors

Institutions

Publication Details

Journal
Engineering and Technology Horizons
Published
2024-12-25
DOI
https://doi.org/10.55003/eth.410405
Primary Topic
Power Quality and Harmonics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experiment of PI Controller for Indirect Current Control for Single – Phase Shunt Active Filter

Wanchak Lenwari, Songklod Sriprang, Anurak Katwattanakul, Kanapot Yodmanee et al.
Engineering and Technology Horizons
Power Quality and Harmonics
article

Experiment of PI Controller for Indirect Current Control for Single – Phase Shunt Active Filter

Wanchak Lenwari, Songklod Sriprang, Anurak Katwattanakul, Kanapot Yodmanee, Sakrit Noosawang
article en

Abstract

Due to harmonic problems caused by various factors that resulted in damages and malfunctions of electrical equipment in the power system, eliminating harmonics in the electrical system has become an important issue for both industrial and household sectors. This article focuses on developing a current control method for a single-phase shunt active power filter (APF) that controls current by an indirect method. The detection of load current to generate reference signals uses the dq-axis reference frame for a single-phase electrical system. The design of circuit parameters and PI controller parameters for compensating current and DC bus voltage are based on a simple calculation method. Simulation and experimental results confirm that the proposed current control method and PI controller design effectively eliminate harmonics, with the percent of total current harmonic distortion (THDi) values of the supply current after compensation within the IEEE Std 519-2022 standard limit.

Engineering and Technology HorizonsVol. 41(4)
Rajamangala University of Technology Isan (TH), Rajamangala University of Technology Rattanakosin (TH), Phetchaburi Rajabhat University (TH), King Mongkut's University of Technology Thonburi (TH)
Thailand Science Research and Innovation
Openalex Percentile: Top 77%
Power Quality and Harmonics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Experiment of PI Controller for Indirect Current Control for Single – Phase Shunt Active Filter — Wanchak Lenwari, Songklod Sriprang, et al. · Engineering and Technology Horizons (2024) | TGRS Research Map | TGRS