Incomplete Data Multisource Static Computed Tomography Reconstruction with Diffusion Priors and Implicit Neural Representation

The dose of X-ray radiation and the scanning time are crucial factors in computed tomography (CT) for clinical applications. In this work, we introduce a multi-source static CT imaging system designed to rapidly acquire sparse view and limited angle data in CT imaging, addressing these critical factors. This linear imaging inverse problem is solved by a conditional generation process within the denoising diffusion image reconstruction framework. The noisy volume data sample generated by the reverse time diffusion process is projected onto the affine set to ensure its consistency to the measured data. To enhance the quality of the reconstruction, the 3D phantom's orthogonal space projector is parameterized implicitly by a neural network. Then, a self-supervised learning algorithm is adopted to optimize the implicit neural representation. Through this multistage conditional generation process, we obtain a new approximate posterior sampling strategy for MSCT volume reconstruction. Numerical experiments are implemented with various imaging settings to verify the effectiveness of our methods for incomplete data MSCT volume reconstruction.

Authors

Institutions

Publication Details

Journal
SIAM Journal on Imaging Sciences
Published
2026-05-19
DOI
https://doi.org/10.1137/24m1722201
Primary Topic
Medical Imaging Techniques and Applications
Type
preprint
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
preprint

Incomplete Data Multisource Static Computed Tomography Reconstruction with Diffusion Priors and Implicit Neural Representation

Haimiao Zhang, Ziju Shen, Bin Dong, Yunxiang Li et al.
SIAM Journal on Imaging Sciences
Medical Imaging Techniques and Applications
preprint

Incomplete Data Multisource Static Computed Tomography Reconstruction with Diffusion Priors and Implicit Neural Representation

Haimiao Zhang, Ziju Shen, Bin Dong, Yunxiang Li, Jun Qiu, Zhili Cui
preprint en

Abstract

The dose of X-ray radiation and the scanning time are crucial factors in computed tomography (CT) for clinical applications. In this work, we introduce a multi-source static CT imaging system designed to rapidly acquire sparse view and limited angle data in CT imaging, addressing these critical factors. This linear imaging inverse problem is solved by a conditional generation process within the denoising diffusion image reconstruction framework. The noisy volume data sample generated by the reverse time diffusion process is projected onto the affine set to ensure its consistency to the measured data. To enhance the quality of the reconstruction, the 3D phantom's orthogonal space projector is parameterized implicitly by a neural network. Then, a self-supervised learning algorithm is adopted to optimize the implicit neural representation. Through this multistage conditional generation process, we obtain a new approximate posterior sampling strategy for MSCT volume reconstruction. Numerical experiments are implemented with various imaging settings to verify the effectiveness of our methods for incomplete data MSCT volume reconstruction.

SIAM Journal on Imaging SciencesVol. 19(2)
Peking University (CN), InferVision (China) (CN), Beijing Information Science & Technology University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 100%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.