Synchronization and Thermal Optimization of a Two-Channel SEPIC Converter System

This paper presents a detailed study of the thermal management and synchronization of a two-channel single-ended primary-inductor converter (SEPIC) system designed to power warning light bulbs in level-crossing signalling devices. The system replaces an older model, offering enhanced electrical performance and more compact dimensions. Thermal optimization is achieved by comparing heat dissipation strategies, including attaching heat sinks to the package top versus the PCB bottom. The analysis shows significant improvements in thermal management with bottom cooling. Additionally, synchronization techniques, particularly through external clocking, are employed to ensure stable operation and mitigate interference between converters. Experimental results validate both the thermal models and synchronization approach, showcasing reduced noise, and reliable converter performance.

Authors

Institutions

Publication Details

Published
2024-11-26
DOI
https://doi.org/10.1109/telfor63250.2024.10819101
Primary Topic
Advanced DC-DC Converters
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Synchronization and Thermal Optimization of a Two-Channel SEPIC Converter System

Ivan Konečný, J. Hammerbauer, Pavel Kučera
Advanced DC-DC Converters
article

Synchronization and Thermal Optimization of a Two-Channel SEPIC Converter System

Ivan Konečný, J. Hammerbauer, Pavel Kučera
article en

Abstract

This paper presents a detailed study of the thermal management and synchronization of a two-channel single-ended primary-inductor converter (SEPIC) system designed to power warning light bulbs in level-crossing signalling devices. The system replaces an older model, offering enhanced electrical performance and more compact dimensions. Thermal optimization is achieved by comparing heat dissipation strategies, including attaching heat sinks to the package top versus the PCB bottom. The analysis shows significant improvements in thermal management with bottom cooling. Additionally, synchronization techniques, particularly through external clocking, are employed to ensure stable operation and mitigate interference between converters. Experimental results validate both the thermal models and synchronization approach, showcasing reduced noise, and reliable converter performance.

University of West Bohemia in Pilsen (CZ)
Affordable and clean energy
Openalex Percentile: Top 77%
Advanced DC-DC Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.