Analysis of the effectiveness of methods for ensuring electromagnetic compatibility of electric drives with active rectifiers in real production conditions

A significant degradation of voltage quality of the in-plant network is possible during operation of electric drives based on a frequency converter with an active rectifier, due to the superposition of high-frequency harmonics of the electric drive current on the resonance region of the network frequency response. Due to the active introduction of such electric drives recently at metallurgical plants, various methods are implemented to ensure electromagnetic compatibility of the frequency converter and the power supply network. The purpose of this study is to analyze the efficiency of methods to ensure electromagnetic compatibility of electric drives and active rectifiers under industrial production. The effectiveness of various methods to improve the power quality in the power distribution system of the enterprise has been evaluated using the developed complex simulation model of the power supply system and electric drives of the hot strip mill. It considers the parameters of the main elements of the electrical complex, as well as the data of experimental studies obtained using the Fluke 435 and ELSPEC G4430 power quality analyzers. Two methods of ensuring electromagnetic compatibility of the frequency converters with active rectifiers are considered. The use of improved algorithms of the active rectifier PWM allows us to reduce the value of the total harmonics distortions at the point of common coupling THDU by 40,1 % to 8,08 %. The installation of a specialized passive filter 9000 kVAr allows us to achieve a significantly greater technical effect (THDU = 0,42 %). The obtained results show that for the enterprise under consideration the optimal option for ensuring the required power quality is the use of specialized passive filter. However, this option will require significant capital and operating costs. The adequacy of the simulation model has been previously confirmed by experimental data and previous studies.

Authors

Publication Details

Journal
Vestnik IGEU
Published
2024-12-28
DOI
https://doi.org/10.17588/2072-2672.2024.6.067-074
Primary Topic
Industrial Engineering and Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of the effectiveness of methods for ensuring electromagnetic compatibility of electric drives with active rectifiers in real production conditions

I.G. Gilemov, A.A. Nikolaev, M.V. Bulanov, V. S. Ivekeev
Vestnik IGEU
Industrial Engineering and Technologies
article

Analysis of the effectiveness of methods for ensuring electromagnetic compatibility of electric drives with active rectifiers in real production conditions

I.G. Gilemov, A.A. Nikolaev, M.V. Bulanov, V. S. Ivekeev
article en

Abstract

A significant degradation of voltage quality of the in-plant network is possible during operation of electric drives based on a frequency converter with an active rectifier, due to the superposition of high-frequency harmonics of the electric drive current on the resonance region of the network frequency response. Due to the active introduction of such electric drives recently at metallurgical plants, various methods are implemented to ensure electromagnetic compatibility of the frequency converter and the power supply network. The purpose of this study is to analyze the efficiency of methods to ensure electromagnetic compatibility of electric drives and active rectifiers under industrial production. The effectiveness of various methods to improve the power quality in the power distribution system of the enterprise has been evaluated using the developed complex simulation model of the power supply system and electric drives of the hot strip mill. It considers the parameters of the main elements of the electrical complex, as well as the data of experimental studies obtained using the Fluke 435 and ELSPEC G4430 power quality analyzers. Two methods of ensuring electromagnetic compatibility of the frequency converters with active rectifiers are considered. The use of improved algorithms of the active rectifier PWM allows us to reduce the value of the total harmonics distortions at the point of common coupling THDU by 40,1 % to 8,08 %. The installation of a specialized passive filter 9000 kVAr allows us to achieve a significantly greater technical effect (THDU = 0,42 %). The obtained results show that for the enterprise under consideration the optimal option for ensuring the required power quality is the use of specialized passive filter. However, this option will require significant capital and operating costs. The adequacy of the simulation model has been previously confirmed by experimental data and previous studies.

Vestnik IGEU(6)
Affordable and clean energy
Openalex Percentile: Top 74%
Industrial Engineering and Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.