Eye lens dose estimations in chest computed tomography examinations using Monte Carlo simulations in a Siemens SOMATOM perspective scanner

Background:The radiation dose received by the eye lens when a chest computed tomography (CT) scan is performed, is generally not recorded in clinical practice, particularly due to the distance of this organ from the X-ray beam.Material and Methods: The absorbed dose in the eye lens was determined by Monte Carlo N-Particle version 5 (MCNP5) calculations and thermoluminescence dosimetry (TLD).Two models of the CT scanner and patient were constructed using the MCNP5 code.The first model was the Bottle Manikin Absorber (BOMAB), which includes the main structures of the eye, and the second was the computational voxelized phantom MAX06.In addition, measurements were carried out in 21 adult patients, which underwent a chest CT study in a Siemens SOMATOM Perspective scanner.Results: Average Monte Carlo values for the absorbed dose of 16.4 0.4 mGy and 1.97 0.04 mSv for the effective dose were obtained when the BOMAB model was used.Mean values of 13.3 0.3 mGy and 1.59 0.04 mSv, respectively, were obtained for the absorbed dose and effective dose for the MAX06 phantom.TLD measurements gave average values of 12.66 1.33 mGy and 1.52 0.16 mSv for absorbed dose and effective dose, respectively, in simple chest scans, and 7.60 0.63 mGy and 0.91 0.07 mSv, respectively, for simple contrast-enhanced studies.Conclusions: The results of the Monte Carlo simulations with BOMAB and voxelized phantoms in our study agree relatively well with each other.

Authors

Institutions

Publication Details

Journal
International Journal of Radiation Research
Published
2024-10-01
DOI
https://doi.org/10.61186/ijrr.22.4.853
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Eye lens dose estimations in chest computed tomography examinations using Monte Carlo simulations in a Siemens SOMATOM perspective scanner

Miguel A. Vallejo, Georgina Waldo, M. Sosa, Enrique Montes et al.
International Journal of Radiation Research
Radiation Dose and Imaging
article

Eye lens dose estimations in chest computed tomography examinations using Monte Carlo simulations in a Siemens SOMATOM perspective scanner

Miguel A. Vallejo, Georgina Waldo, M. Sosa, Enrique Montes, Uvaldo Reyes, L. Gutiérrez, Pablo Cerón, Betsy Quispe, Javier Pena, Mey León, María Antonia Gil Hernández, H. Vega
article en

Abstract

Background:The radiation dose received by the eye lens when a chest computed tomography (CT) scan is performed, is generally not recorded in clinical practice, particularly due to the distance of this organ from the X-ray beam.Material and Methods: The absorbed dose in the eye lens was determined by Monte Carlo N-Particle version 5 (MCNP5) calculations and thermoluminescence dosimetry (TLD).Two models of the CT scanner and patient were constructed using the MCNP5 code.The first model was the Bottle Manikin Absorber (BOMAB), which includes the main structures of the eye, and the second was the computational voxelized phantom MAX06.In addition, measurements were carried out in 21 adult patients, which underwent a chest CT study in a Siemens SOMATOM Perspective scanner.Results: Average Monte Carlo values for the absorbed dose of 16.4 0.4 mGy and 1.97 0.04 mSv for the effective dose were obtained when the BOMAB model was used.Mean values of 13.3 0.3 mGy and 1.59 0.04 mSv, respectively, were obtained for the absorbed dose and effective dose for the MAX06 phantom.TLD measurements gave average values of 12.66 1.33 mGy and 1.52 0.16 mSv for absorbed dose and effective dose, respectively, in simple chest scans, and 7.60 0.63 mGy and 0.91 0.07 mSv, respectively, for simple contrast-enhanced studies.Conclusions: The results of the Monte Carlo simulations with BOMAB and voxelized phantoms in our study agree relatively well with each other.

International Journal of Radiation ResearchVol. 22(4)
Universidad de Guanajuato (MX), University of Quintana Roo (MX), Mexican Social Security Institute (MX), Universidad Juárez del Estado de Durango (MX), Durango Institute of Technology (MX), Autonomous University of Durango (MX), Universidad Autónoma de Zacatecas "Francisco García Salinas" (MX)
Universidad de Guanajuato
Openalex Percentile: Top 58%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.