Study of dose response, luminescence kinetics, and reading modes combination advantage of TLD-100H radiation dosimeter

Background: This study investigates various aspects of TLD-100H radiation dosimeter, including luminescence kinetics, dose response, and the effects of the combination of thermally stimulated (TL) and optically stimulated (OSL) luminescence modes. Materials and Methods:The TL kinetic parameters were determined using general order kinetics via computerized glow-curve deconvolution (GOK-CGCD).OSL decay curves and kinetics were also investigated through OSL signal decomposition.The dose response was studied for a practical dose range of 2-80 Gy.Interesting OSL and TL reading modes combination were also tested.Results: The identified dosimetric peak at ~560 K was deconvoluted into two main peaks (553K and 568K).The dose response study reveals a sublinear behaviour within the considered dose range.Two dominating types of fast and slowly decaying OSL traps were identified.Indicative values of detrapping probabilities and photoexcitation cross sections of these OSL traps are thus provided.Results of TL and OSL reading modes combination demonstrate well that measuring TL signal before OSL resulted in almost complete erasure of the OSL signal.Additionally, an increase in TL integral intensity by ~+10% was observed when OSL measured firstly, likely due to the emptying of a limited number of lower temperature shallow traps by OSL.Indeed, these no longer applied a screen effect for the higher temperature traps, making their release more prominent in TL reading mode.Consequently, improving or optimizing the TL signal.Conclusions: These findings contribute to a better understanding of TLD-100H's behaviour and support its reliability as a radiation dosimeter in medical physics.

Authors

Institutions

Publication Details

Journal
International Journal of Radiation Research
Published
2024-10-01
DOI
https://doi.org/10.61186/ijrr.22.4.1079
Primary Topic
Radiation Detection and Scintillator Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study of dose response, luminescence kinetics, and reading modes combination advantage of TLD-100H radiation dosimeter

Chahra‐Zed Benkhelifa, Eren Şahi̇ner, Fayçal Kharfi, A. Mezaache
International Journal of Radiation Research
Radiation Detection and Scintillator Technologies
article

Study of dose response, luminescence kinetics, and reading modes combination advantage of TLD-100H radiation dosimeter

Chahra‐Zed Benkhelifa, Eren Şahi̇ner, Fayçal Kharfi, A. Mezaache
article en

Abstract

Background: This study investigates various aspects of TLD-100H radiation dosimeter, including luminescence kinetics, dose response, and the effects of the combination of thermally stimulated (TL) and optically stimulated (OSL) luminescence modes. Materials and Methods:The TL kinetic parameters were determined using general order kinetics via computerized glow-curve deconvolution (GOK-CGCD).OSL decay curves and kinetics were also investigated through OSL signal decomposition.The dose response was studied for a practical dose range of 2-80 Gy.Interesting OSL and TL reading modes combination were also tested.Results: The identified dosimetric peak at ~560 K was deconvoluted into two main peaks (553K and 568K).The dose response study reveals a sublinear behaviour within the considered dose range.Two dominating types of fast and slowly decaying OSL traps were identified.Indicative values of detrapping probabilities and photoexcitation cross sections of these OSL traps are thus provided.Results of TL and OSL reading modes combination demonstrate well that measuring TL signal before OSL resulted in almost complete erasure of the OSL signal.Additionally, an increase in TL integral intensity by ~+10% was observed when OSL measured firstly, likely due to the emptying of a limited number of lower temperature shallow traps by OSL.Indeed, these no longer applied a screen effect for the higher temperature traps, making their release more prominent in TL reading mode.Consequently, improving or optimizing the TL signal.Conclusions: These findings contribute to a better understanding of TLD-100H's behaviour and support its reliability as a radiation dosimeter in medical physics.

International Journal of Radiation ResearchVol. 22(4)
Ankara University (TR), University Ferhat Abbas of Setif (DZ)
Quality Education
Openalex Percentile: Top 66%
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Study of dose response, luminescence kinetics, and reading modes combination advantage of TLD-100H radiation dosimeter — Chahra‐Zed Benkhelifa, Eren Şahi̇ner, et al. · International Journal of Radiation Research (2024) | TGRS Research Map | TGRS