Numerical Study on the Shear Behavior of a Late-Model Cold-Formed Stainless Steel C-Shaped Beam

The failure mode of thin-walled C-channel beams typically manifests as premature local buckling of the compression flange, leading to insufficient utilization of material strength in both the flange and the web. To address this issue, this study adopts the approach of increasing the number of bends to reinforce the flange and adding V-shaped stiffeners in the middle of the web to reduce the width-to-thickness ratio of the plate elements, thereby delaying local buckling and allowing for greater plastic deformation. However, the challenge lies in the irregular cross-sectional shape and complex buckling patterns. Therefore, this paper aims to explore a suitable cross-sectional form to expand the application of stainless steel members. Subsequently, three-point bending tests were conducted on the optimally designed stainless C-channel beam with folded flanges and mid-web stiffeners. The finite element simulation results were compared and analyzed with the experimental results to validate the model's effectiveness. After verifying the correctness of the finite element model, this study conducted numerical parameterization research to investigate the effects of the shear span ratio, complex edge stiffeners, web height-thickness ratio, and V-shaped stiffener size on the shear performance of stainless steel folded flange C-beams. The results show that changing the shear span ratio has a significant impact on the shear capacity and vertical deflection deformation of components; increasing the web height-thickness ratio can enhance the shear capacity of the component; elevating the V-shaped stiffener size can slightly improve the shear capacity of components; and for the stainless steel C-shaped beam with folded flanges and intermediate stiffening webs, adding edge stiffeners cannot remarkably promote the shear capacity of the component.

Authors

Institutions

Publication Details

Journal
Materials
Published
2024-12-28
DOI
https://doi.org/10.3390/ma18010091
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical Study on the Shear Behavior of a Late-Model Cold-Formed Stainless Steel C-Shaped Beam

Zhenglin Zhang, Zhong Tao, Ji Zhang, Shuang-E Huangfu et al.
Materials
Structural Load-Bearing Analysis
article

Numerical Study on the Shear Behavior of a Late-Model Cold-Formed Stainless Steel C-Shaped Beam

Zhenglin Zhang, Zhong Tao, Ji Zhang, Shuang-E Huangfu, Zihao Wang
article en

Abstract

The failure mode of thin-walled C-channel beams typically manifests as premature local buckling of the compression flange, leading to insufficient utilization of material strength in both the flange and the web. To address this issue, this study adopts the approach of increasing the number of bends to reinforce the flange and adding V-shaped stiffeners in the middle of the web to reduce the width-to-thickness ratio of the plate elements, thereby delaying local buckling and allowing for greater plastic deformation. However, the challenge lies in the irregular cross-sectional shape and complex buckling patterns. Therefore, this paper aims to explore a suitable cross-sectional form to expand the application of stainless steel members. Subsequently, three-point bending tests were conducted on the optimally designed stainless C-channel beam with folded flanges and mid-web stiffeners. The finite element simulation results were compared and analyzed with the experimental results to validate the model's effectiveness. After verifying the correctness of the finite element model, this study conducted numerical parameterization research to investigate the effects of the shear span ratio, complex edge stiffeners, web height-thickness ratio, and V-shaped stiffener size on the shear performance of stainless steel folded flange C-beams. The results show that changing the shear span ratio has a significant impact on the shear capacity and vertical deflection deformation of components; increasing the web height-thickness ratio can enhance the shear capacity of the component; elevating the V-shaped stiffener size can slightly improve the shear capacity of components; and for the stainless steel C-shaped beam with folded flanges and intermediate stiffening webs, adding edge stiffeners cannot remarkably promote the shear capacity of the component.

MaterialsVol. 18(1)
Kunming University of Science and Technology (CN), CCCC Highway Consultants (China) (CN), China Railway Construction Corporation (China) (CN)
Sustainable cities and communities
Openalex Percentile: Top 72%
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.