Comparison of hemodynamic responses to orotracheal intubation with Tuoren video laryngoscope and Macintosh direct laryngoscope in adult hypertensive patients

Background: Laryngoscopy and intubation lead to unfavorable hemodynamic responses. Many studies have already compared direct laryngoscope (DL) and different types of video laryngoscopes (VLs). While some of those reported favorable response with use of VL, others have depicted an unfavorable response with VL. Aims and Objectives: Hence, the present study was carried out to compare the hemodynamic response to laryngoscopy between use of Macintosh DL and Tuoren VL in controlled hypertensive patients during elective surgery. Materials and Methods: A total of 122 patients were recruited for this interventional study. Patients were allocated into two groups to have their intubation with Tuoren VL (Group V, n=61) or Macintosh DL (Group D, n=61). The mean arterial pressure (MAP) at 1 min after intubation was the primary outcome. Other outcome measures were to compare heart rate (HR) at different time points, procedure time (glottis exposure time and intubation time), and number of attempts. Results: The use of DL led to considerably higher MAP at 1, 3, and 5 min after laryngoscopy and intubation compared with VL. However, comparable HRs were found between the two groups at such time points. Glottis visualization time and intubation time were considerably higher using VL compared with DL. The mean total procedure time was considerably lesser with DL over VL (mean, 29.5 vs. 38.5 s, respectively, <0.001). Conclusion: Tuoren video laryngoscope can be a better alternative to Macintosh direct laryngoscope in view of considerably lesser rise of mean arterial pressure and comparable heart rate during laryngoscopy and intubation in hypertensive patient.

Authors

Institutions

Publication Details

Journal
Asian Journal of Medical Sciences
Published
2024-11-02
DOI
https://doi.org/10.71152/ajms.v15i11.4234
Primary Topic
Airway Management and Intubation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of hemodynamic responses to orotracheal intubation with Tuoren video laryngoscope and Macintosh direct laryngoscope in adult hypertensive patients

Mohanchandra Mandal, Sangita Mandal, Debojyoti Das, Sarfraaz Rahman et al.
Asian Journal of Medical Sciences
Airway Management and Intubation Techniques
article

Comparison of hemodynamic responses to orotracheal intubation with Tuoren video laryngoscope and Macintosh direct laryngoscope in adult hypertensive patients

Mohanchandra Mandal, Sangita Mandal, Debojyoti Das, Sarfraaz Rahman, Soma Chakraborty, Pradip Roy, Debjani Gayen
article en

Abstract

Background: Laryngoscopy and intubation lead to unfavorable hemodynamic responses. Many studies have already compared direct laryngoscope (DL) and different types of video laryngoscopes (VLs). While some of those reported favorable response with use of VL, others have depicted an unfavorable response with VL. Aims and Objectives: Hence, the present study was carried out to compare the hemodynamic response to laryngoscopy between use of Macintosh DL and Tuoren VL in controlled hypertensive patients during elective surgery. Materials and Methods: A total of 122 patients were recruited for this interventional study. Patients were allocated into two groups to have their intubation with Tuoren VL (Group V, n=61) or Macintosh DL (Group D, n=61). The mean arterial pressure (MAP) at 1 min after intubation was the primary outcome. Other outcome measures were to compare heart rate (HR) at different time points, procedure time (glottis exposure time and intubation time), and number of attempts. Results: The use of DL led to considerably higher MAP at 1, 3, and 5 min after laryngoscopy and intubation compared with VL. However, comparable HRs were found between the two groups at such time points. Glottis visualization time and intubation time were considerably higher using VL compared with DL. The mean total procedure time was considerably lesser with DL over VL (mean, 29.5 vs. 38.5 s, respectively, <0.001). Conclusion: Tuoren video laryngoscope can be a better alternative to Macintosh direct laryngoscope in view of considerably lesser rise of mean arterial pressure and comparable heart rate during laryngoscopy and intubation in hypertensive patient.

Asian Journal of Medical SciencesVol. 15(11)
Bankura Sammilani Medical College (IN), Institute of Post Graduate Medical Education and Research (IN), Government Medical College (IN), Medical College and Hospital, Kolkata (IN)
Openalex Percentile: Top 55%
Airway Management and Intubation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies