Electrophoretic Deposition of Gentamicin Into Titania Nanotubes Prevents Evidence of Infection in a Mouse Model of Periprosthetic Joint Infection

Periprosthetic joint infection (PJI) is a leading cause and major complication of joint replacement failure. As opposed to standard-of-care systemic antibiotic prophylaxis for PJI, we developed and tested titanium femoral intramedullary implants with titania nanotubes (TNTs) coated with the antibiotic gentamicin and slow-release agent chitosan through electrophoretic deposition (EPD) in a mouse model of PJI. We hypothesized that these implants would enable local gentamicin delivery to the implant surface and surgical site, effectively preventing bacterial colonization. In the mouse PJI model, C57BL/6 mice received implants with TNTs coated with chitosan (chitosan group; control group) or with TNTs coated with chitosan and gentamicin (chitosan + gentamicin group; experimental group). Following implant placement, the surgical site was inoculated with 1 × 10<sup>3</sup> CFUs of Xen36 bioluminescent Staphylococcus aureus. All the mice in the chitosan group and none in the chitosan + gentamicin group had evidence of infection based on CFU analysis and bioluminescence imaging through the 14-day assessment postsurgery. Correspondingly, scanning electron microscopy analysis at the implant surface demonstrated bacterial biofilm only in the chitosan group. Furthermore, periosteal reaction and peri-implant bone loss at the femur were significantly reduced in the chitosan + gentamicin group. The chitosan + gentamicin group had reduced pain behavior, improved weight-bearing, and increased weight compared to the chitosan-control group. This study provides preclinical evidence supporting the efficacy of implants with TNTs coated with chitosan and gentamicin through EPD for preventing bacterial colonization and biofilm formation in a mouse model of PJI.

Authors

Institutions

Publication Details

Journal
Journal of Orthopaedic Research®
Published
2024-12-31
DOI
https://doi.org/10.1002/jor.26029
Citations
3
Primary Topic
Bone Tissue Engineering Materials
Type
article
Field-Weighted Citation Impact
0.55

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrophoretic Deposition of Gentamicin Into Titania Nanotubes Prevents Evidence of Infection in a Mouse Model of Periprosthetic Joint Infection

Adrienn Markovics, Amandine Impergre, John L. Hamilton, Mohammad Abualia et al.
3 citations
Journal of Orthopaedic Research®
Bone Tissue Engineering Materials
0.55
article

Electrophoretic Deposition of Gentamicin Into Titania Nanotubes Prevents Evidence of Infection in a Mouse Model of Periprosthetic Joint Infection

Adrienn Markovics, Amandine Impergre, John L. Hamilton, Mohammad Abualia, Markus A. Wimmer, Alfons Fischer, Greta Della Fara, Sofia Gianotti, Francesca De Vecchi, Julia Fischer
article en
3 citations

Abstract

Periprosthetic joint infection (PJI) is a leading cause and major complication of joint replacement failure. As opposed to standard-of-care systemic antibiotic prophylaxis for PJI, we developed and tested titanium femoral intramedullary implants with titania nanotubes (TNTs) coated with the antibiotic gentamicin and slow-release agent chitosan through electrophoretic deposition (EPD) in a mouse model of PJI. We hypothesized that these implants would enable local gentamicin delivery to the implant surface and surgical site, effectively preventing bacterial colonization. In the mouse PJI model, C57BL/6 mice received implants with TNTs coated with chitosan (chitosan group; control group) or with TNTs coated with chitosan and gentamicin (chitosan + gentamicin group; experimental group). Following implant placement, the surgical site was inoculated with 1 × 10<sup>3</sup> CFUs of Xen36 bioluminescent Staphylococcus aureus. All the mice in the chitosan group and none in the chitosan + gentamicin group had evidence of infection based on CFU analysis and bioluminescence imaging through the 14-day assessment postsurgery. Correspondingly, scanning electron microscopy analysis at the implant surface demonstrated bacterial biofilm only in the chitosan group. Furthermore, periosteal reaction and peri-implant bone loss at the femur were significantly reduced in the chitosan + gentamicin group. The chitosan + gentamicin group had reduced pain behavior, improved weight-bearing, and increased weight compared to the chitosan-control group. This study provides preclinical evidence supporting the efficacy of implants with TNTs coated with chitosan and gentamicin through EPD for preventing bacterial colonization and biofilm formation in a mouse model of PJI.

Journal of Orthopaedic Research®Vol. 43(3)
Rush University Medical Center (US), Max-Planck-Institut für Nachhaltige Materialien (DE)
National Institutes of Health, National Institute of Arthritis and Musculoskeletal and Skin Diseases
Good health and well-being
Openalex Percentile: Top 35%
Bone Tissue Engineering Materials
0.55
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.