TOURNIQUET APPLICATION TIME DURING PHLEBOTOMY AFFECTS BIOCHEMICAL TESTING

Introduction: Venous blood sampling is usually performed using a tourniquet to help locate and dene peripheral veins to achieve successful and safe venepuncture. In developing countries like India, there is lack of understanding about good laboratory practices and inadequate training to phlebotomists, compelling them to make errors during phlebotomy. The improper venous accesses or prolonged venous stasis created by tourniquet application will result in collection of unsuitable blood sample. Methods: The present study was conducted at one of the tertiary care hospital at State Capital to nd out the effect of tourniquet application time on 17 common biochemical analytes in 20 fasting healthy adult volunteers. Sequential venepunctures were performed by a single expert phlebotomist either without venous stasis or following the application of standardized external pressure of 60 mm Hg using a sphygmomanometer for 1, 3 and 6 minutes. Biochemical parameters were analyzed on Fully Automated Analyzer Olympus AU 680 by using standard protocol of commercially available kits. Results: ALT concentration was signicantly high in samples collected after application of external pressure for 3min (P<0.05) and 6min (P<0.01); Alkaline phosphatase, LDH, Creatine kinase, Total Cholesterol, Triglyceride, Total Protein, Albumin and Calcium concentrations were signicantly high in samples collected after application of external pressure for 6min (P<0.05) as compared to samples collected without venous stasis. There were no signicant alterations in rest biochemical analytes concentrations (Glucose, Urea, Creatinine, AST, Uric Acid, Phosphorus, Sodium, and Potassium) even after 6 min venous stasis. Conclusion: Venous stasis from tourniquet placement during venepuncture should be minimized, as it accounts for spurious and signicant variations for several biochemical analytes.

Authors

Institutions

Publication Details

Journal
GLOBAL JOURNAL FOR RESEARCH ANALYSIS
Published
2024-12-15
DOI
https://doi.org/10.36106/gjra/5905562
Primary Topic
Trauma, Hemostasis, Coagulopathy, Resuscitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

TOURNIQUET APPLICATION TIME DURING PHLEBOTOMY AFFECTS BIOCHEMICAL TESTING

Monika Gupta, Shikha Gupta
GLOBAL JOURNAL FOR RESEARCH ANALYSIS
Trauma, Hemostasis, Coagulopathy, Resuscitation
article

TOURNIQUET APPLICATION TIME DURING PHLEBOTOMY AFFECTS BIOCHEMICAL TESTING

Monika Gupta, Shikha Gupta
article en

Abstract

Introduction: Venous blood sampling is usually performed using a tourniquet to help locate and dene peripheral veins to achieve successful and safe venepuncture. In developing countries like India, there is lack of understanding about good laboratory practices and inadequate training to phlebotomists, compelling them to make errors during phlebotomy. The improper venous accesses or prolonged venous stasis created by tourniquet application will result in collection of unsuitable blood sample. Methods: The present study was conducted at one of the tertiary care hospital at State Capital to nd out the effect of tourniquet application time on 17 common biochemical analytes in 20 fasting healthy adult volunteers. Sequential venepunctures were performed by a single expert phlebotomist either without venous stasis or following the application of standardized external pressure of 60 mm Hg using a sphygmomanometer for 1, 3 and 6 minutes. Biochemical parameters were analyzed on Fully Automated Analyzer Olympus AU 680 by using standard protocol of commercially available kits. Results: ALT concentration was signicantly high in samples collected after application of external pressure for 3min (P<0.05) and 6min (P<0.01); Alkaline phosphatase, LDH, Creatine kinase, Total Cholesterol, Triglyceride, Total Protein, Albumin and Calcium concentrations were signicantly high in samples collected after application of external pressure for 6min (P<0.05) as compared to samples collected without venous stasis. There were no signicant alterations in rest biochemical analytes concentrations (Glucose, Urea, Creatinine, AST, Uric Acid, Phosphorus, Sodium, and Potassium) even after 6 min venous stasis. Conclusion: Venous stasis from tourniquet placement during venepuncture should be minimized, as it accounts for spurious and signicant variations for several biochemical analytes.

GLOBAL JOURNAL FOR RESEARCH ANALYSIS
SMS Medical College (IN)
Partnerships for the goals
Openalex Percentile: Top 68%
Trauma, Hemostasis, Coagulopathy, Resuscitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

TOURNIQUET APPLICATION TIME DURING PHLEBOTOMY AFFECTS BIOCHEMICAL TESTING — Monika Gupta, Shikha Gupta · GLOBAL JOURNAL FOR RESEARCH ANALYSIS (2024) | TGRS Research Map | TGRS