Interfacial adaptation and ion release of bioceramic sealer in infectious environment

This work used energy dispersive X-ray spectroscopy (EDX) and scanning electron microscopy (SEM) to evaluate and compare the ion release and interfacial adaptability of two bioceramic sealants (Dia-Root and One-Fil sealers) under standard circumstances (PBS) and in infectious environments. Methods: Eighty dentin slices with standardized canal spaces were divided into two groups (n = 40 each) and sealed with Dia-Root and One-Fil sealants. Each set was partitioned into two subgroups (n = 20) based on the experimental liquids: (a) PBS (pH 7.4) and (b) 1 mmol/L butyric acid (pH 5.4). The specimens were then cultured for seven days at 37 degrees Celsius. The ion release was examined utilizing EDX. Scanning Electron Microscopy (SEM) will be employed to examine the marginal gap at the contact between the sealer and root dentin. Subsequently, a statistical analysis of the collected values was conducted. Outcomes: One-Fil bioceramic sealant released a greater quantity of calcium ions than Dia-Root BIO Sealer when subjected to acid treatment; nonetheless, the difference between the sealers was not statistically significant. Phosphorus was identified in all sealing specimens exposed to PBS, but not in those submitted to butyric acid. Moreover, the EDX analysis of the evaluated sealers exposed to PBS revealed mean Ca/P ratios exceeding the natural hydroxyapatite (HAP) ratio of 1.67. No statistically significant change was seen in the gap width between the tested sealants exposed to acid and dentin (P > 0.05). The mean and standard deviation for Dia-Root and One-Fil bioceramic sealants subjected to PBS were calculated, revealing that Dia-Root BIO Sealer had the smallest gap, whilst One-Fil exhibited the biggest gap. Conclusions: All analyzed sealers (Dia-Root and One-Fil) generate calcium, aluminum, and oxygen ions across all storage media. Acidic environments affect the interfacial adaptation of the evaluated bioceramic sealers to root canal dentin, as the statistically significant mean gap width of all tested sealers exposed to butyric acid was larger than that of the same sealers exposed to PBS.

Authors

Publication Details

Journal
National Journal of Clinical Orthopaedics
Published
2024-10-01
DOI
https://doi.org/10.33545/orthor.2024.v8.i4.a.456
Primary Topic
Bone Tissue Engineering Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Interfacial adaptation and ion release of bioceramic sealer in infectious environment

Amina A. Younis, Ashraf S Alchalabi
National Journal of Clinical Orthopaedics
Bone Tissue Engineering Materials
article

Interfacial adaptation and ion release of bioceramic sealer in infectious environment

Amina A. Younis, Ashraf S Alchalabi
article en

Abstract

This work used energy dispersive X-ray spectroscopy (EDX) and scanning electron microscopy (SEM) to evaluate and compare the ion release and interfacial adaptability of two bioceramic sealants (Dia-Root and One-Fil sealers) under standard circumstances (PBS) and in infectious environments. Methods: Eighty dentin slices with standardized canal spaces were divided into two groups (n = 40 each) and sealed with Dia-Root and One-Fil sealants. Each set was partitioned into two subgroups (n = 20) based on the experimental liquids: (a) PBS (pH 7.4) and (b) 1 mmol/L butyric acid (pH 5.4). The specimens were then cultured for seven days at 37 degrees Celsius. The ion release was examined utilizing EDX. Scanning Electron Microscopy (SEM) will be employed to examine the marginal gap at the contact between the sealer and root dentin. Subsequently, a statistical analysis of the collected values was conducted. Outcomes: One-Fil bioceramic sealant released a greater quantity of calcium ions than Dia-Root BIO Sealer when subjected to acid treatment; nonetheless, the difference between the sealers was not statistically significant. Phosphorus was identified in all sealing specimens exposed to PBS, but not in those submitted to butyric acid. Moreover, the EDX analysis of the evaluated sealers exposed to PBS revealed mean Ca/P ratios exceeding the natural hydroxyapatite (HAP) ratio of 1.67. No statistically significant change was seen in the gap width between the tested sealants exposed to acid and dentin (P > 0.05). The mean and standard deviation for Dia-Root and One-Fil bioceramic sealants subjected to PBS were calculated, revealing that Dia-Root BIO Sealer had the smallest gap, whilst One-Fil exhibited the biggest gap. Conclusions: All analyzed sealers (Dia-Root and One-Fil) generate calcium, aluminum, and oxygen ions across all storage media. Acidic environments affect the interfacial adaptation of the evaluated bioceramic sealers to root canal dentin, as the statistically significant mean gap width of all tested sealers exposed to butyric acid was larger than that of the same sealers exposed to PBS.

National Journal of Clinical OrthopaedicsVol. 8(4)
Openalex Percentile: Top 77%
Bone Tissue Engineering Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Interfacial adaptation and ion release of bioceramic sealer in infectious environment — Amina A. Younis, Ashraf S Alchalabi · National Journal of Clinical Orthopaedics (2024) | TGRS Research Map | TGRS