A Water Absorption Chamber Design for Cable Capacitance Measurement Tests

XLPO cables used in ships should be tested for water absorption. Test standards require the cables be submerged in a water absorption chamber and kept at 75 0C for 14 days. Once every 7 days, the cables within the chamber are tested by applying high voltage, and their capacitance, dissipation factor, stability factor, and relative Permittivity are measured. In this study, a water absorption chamber used in the experiments is designed using fiberglass material and controlled with an ENDA ET 4420 temperature controller. It is experimentally shown that the water absorption chamber performs well.

Authors

Institutions

Publication Details

Journal
European Journal of Engineering and Applied Sciences
Published
2024-12-31
DOI
https://doi.org/10.55581/ejeas.1598086
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Water Absorption Chamber Design for Cable Capacitance Measurement Tests

Reşat MUTLU, Uğur Akyol, Metin Yurtsever, Avşin Öztaş et al.
European Journal of Engineering and Applied Sciences
Advanced Fiber Optic Sensors
article

A Water Absorption Chamber Design for Cable Capacitance Measurement Tests

Reşat MUTLU, Uğur Akyol, Metin Yurtsever, Avşin Öztaş, Ercan Ulutay
article en

Abstract

XLPO cables used in ships should be tested for water absorption. Test standards require the cables be submerged in a water absorption chamber and kept at 75 0C for 14 days. Once every 7 days, the cables within the chamber are tested by applying high voltage, and their capacitance, dissipation factor, stability factor, and relative Permittivity are measured. In this study, a water absorption chamber used in the experiments is designed using fiberglass material and controlled with an ENDA ET 4420 temperature controller. It is experimentally shown that the water absorption chamber performs well.

European Journal of Engineering and Applied SciencesVol. 7(2)
Tekirdağ Namık Kemal University (TR), Universal College (PH)
Openalex Percentile: Top 77%
Advanced Fiber Optic Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.