Measurements of Water-Equivalent Diameter (Dw) Based on Localizer Radiograph for Tube Voltage Variation

This study aims to investigate the step-wedge phantom for calibrating CT localizer radiograph for different tube voltages. The in-house step-wedge phantom has five steps with thicknesses of 6, 12, 18, 24, and 30 cm. The phantom was scanned using a 64-slice Siemens Definition AS CT scanner at tube voltages of 80, 100, 120, 140, and 160 kVp. The relationship between pixel values (PV) and water-equivalent thickness (tw) was obtained for different step thicknesses. This relationship was used to calibrate the CT localizer radiograph for measuring water-equivalent (Dw) and size-specific dose estimate (SSDE). The results of Dw and SSDE from the localizer radiograph were compared with those calculated from axial CT images. It is found that tube voltage (kVp) can affect the accuracy of Water-Equivalent Diameter (DW) measurements in localizer radiograph imaging. Lower tube voltages tend to increase image contrast but may also increase noise, while higher voltages can reduce contrast while producing images with better penetration and higher radiation doses.

Authors

Institutions

Publication Details

Journal
International Journal of Scientific Research in Science and Technology
Published
2024-12-27
DOI
https://doi.org/10.32628/ijsrst24114333
Primary Topic
Non-Destructive Testing Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurements of Water-Equivalent Diameter (Dw) Based on Localizer Radiograph for Tube Voltage Variation

Heri Sutanto, Sitti M Rif’ah, Choirul Anam, Heryani Cholid et al.
International Journal of Scientific Research in Science and Technology
Non-Destructive Testing Techniques
article

Measurements of Water-Equivalent Diameter (Dw) Based on Localizer Radiograph for Tube Voltage Variation

Heri Sutanto, Sitti M Rif’ah, Choirul Anam, Heryani Cholid, Vika Abidah
article en

Abstract

This study aims to investigate the step-wedge phantom for calibrating CT localizer radiograph for different tube voltages. The in-house step-wedge phantom has five steps with thicknesses of 6, 12, 18, 24, and 30 cm. The phantom was scanned using a 64-slice Siemens Definition AS CT scanner at tube voltages of 80, 100, 120, 140, and 160 kVp. The relationship between pixel values (PV) and water-equivalent thickness (tw) was obtained for different step thicknesses. This relationship was used to calibrate the CT localizer radiograph for measuring water-equivalent (Dw) and size-specific dose estimate (SSDE). The results of Dw and SSDE from the localizer radiograph were compared with those calculated from axial CT images. It is found that tube voltage (kVp) can affect the accuracy of Water-Equivalent Diameter (DW) measurements in localizer radiograph imaging. Lower tube voltages tend to increase image contrast but may also increase noise, while higher voltages can reduce contrast while producing images with better penetration and higher radiation doses.

International Journal of Scientific Research in Science and TechnologyVol. 11(6)
Diponegoro University (ID), Universitas Pekalongan (ID)
Clean water and sanitation
Openalex Percentile: Top 74%
Non-Destructive Testing Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.