Performance of PMMA/Ta2O5 Composites as Medical Radiation Shielding: WinXCom and MCNP6 Studies

The growing reliance on radiation in contemporary applications underscores the imperative to safeguard individuals and the environment from harmful consequences. To mitigate the adverse effects of radiation, polymer composites have begun to garner interest from researchers as potential lead-free shielding materials, largely due to their distinctive attributes, including flexibility, lightness, and environmental benignity. In this study, the gamma radiation shielding capacity of polymethyl methacrylate (PMMA) composites reinforced with varying proportions of Ta₂O₅ (5%, 10%, and 20% wt) was investigated through the utilization of Windows version of photon cross sections on a personal computer (WinXCom) software and the Monte Carlo N-Particle 6 (MCNP6) code. The alignment of the WinXCom and MCNP6 results, despite their different methodologies, provides a robust and reliable understanding of the radiation shielding performance of these composites. The present study investigated the radiation attenuation properties of PMMA/Ta₂O₅ composites about shielding coefficients, including mass attenuation coefficients (MAC), half-value layer (HVL), and effective atomic number (Zeff). The findings indicated that all composites demonstrated enhanced shielding performance compared to pure PMMA. The PMMA/20% Ta₂O₅ composite exhibited MAC values of 1.22-, 1.29-, and 1.28-fold greater than those observed in the silicon-based composites. The MAC increase was observed in the PMMA/20% Ta₂O₅ composite at an energy of 81 keV. The PMMA/20% Ta₂O₅ composite demonstrated the most effective radiation shielding properties. In light of these findings, the PMMA/20% Ta₂O₅ composite can be regarded as a flexible, lightweight, and environmentally friendly shielding material, reassuring these composites' reliability in practical applications.

Authors

Institutions

Publication Details

Journal
Journal of Advanced Research in Natural and Applied Sciences
Published
2024-12-31
DOI
https://doi.org/10.28979/jarnas.1559903
Citations
1
Primary Topic
Radiation Shielding Materials Analysis
Type
article
Field-Weighted Citation Impact
0.12
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance of PMMA/Ta2O5 Composites as Medical Radiation Shielding: WinXCom and MCNP6 Studies

Mustafa Çağlar
1 citations
Journal of Advanced Research in Natural and Applied Sciences
Radiation Shielding Materials Analysis
0.12
article

Performance of PMMA/Ta2O5 Composites as Medical Radiation Shielding: WinXCom and MCNP6 Studies

Mustafa Çağlar
article en
1 citations

Abstract

The growing reliance on radiation in contemporary applications underscores the imperative to safeguard individuals and the environment from harmful consequences. To mitigate the adverse effects of radiation, polymer composites have begun to garner interest from researchers as potential lead-free shielding materials, largely due to their distinctive attributes, including flexibility, lightness, and environmental benignity. In this study, the gamma radiation shielding capacity of polymethyl methacrylate (PMMA) composites reinforced with varying proportions of Ta₂O₅ (5%, 10%, and 20% wt) was investigated through the utilization of Windows version of photon cross sections on a personal computer (WinXCom) software and the Monte Carlo N-Particle 6 (MCNP6) code. The alignment of the WinXCom and MCNP6 results, despite their different methodologies, provides a robust and reliable understanding of the radiation shielding performance of these composites. The present study investigated the radiation attenuation properties of PMMA/Ta₂O₅ composites about shielding coefficients, including mass attenuation coefficients (MAC), half-value layer (HVL), and effective atomic number (Zeff). The findings indicated that all composites demonstrated enhanced shielding performance compared to pure PMMA. The PMMA/20% Ta₂O₅ composite exhibited MAC values of 1.22-, 1.29-, and 1.28-fold greater than those observed in the silicon-based composites. The MAC increase was observed in the PMMA/20% Ta₂O₅ composite at an energy of 81 keV. The PMMA/20% Ta₂O₅ composite demonstrated the most effective radiation shielding properties. In light of these findings, the PMMA/20% Ta₂O₅ composite can be regarded as a flexible, lightweight, and environmentally friendly shielding material, reassuring these composites' reliability in practical applications.

Journal of Advanced Research in Natural and Applied SciencesVol. 10(4)
Istanbul Medipol University (TR)
Affordable and clean energy
Openalex Percentile: Top 56%
Radiation Shielding Materials Analysis
0.12
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Performance of PMMA/Ta2O5 Composites as Medical Radiation Shielding: WinXCom and MCNP6 Studies — Mustafa Çağlar · Journal of Advanced Research in Natural and Applied Sciences (2024) | TGRS Research Map | TGRS