Ablation of Polyester Capillaries by Electrothermal Pulsed Plasma Discharge

Plasma propulsion systems have become the most attractive systems for satellite engines due to their simplicity and reliability. This research was carried out to manufacture an electrothermal pulsed plasma thruster system using a polyester capillary. This study includes a measurement of ablated mass with different input voltage values and with increasing in the number of shots. It was found that by increasing the input voltage from 1.5 kV to 4 kV, the ablated mass increases from 120.6 µg to 432.6 µg. The experimental results were compared to the theoretical data obtained from the ETFLOW model; the calculated ablated mass increased from 136 µg to 447 µg, which is in good agreement with the measured results. Also, the model was used to study the behavior of some physical parameters with discharge time, such as plasma density, velocity, and temperature. Finally, the exit velocity was calculated as a function of peak current.

Authors

Institutions

Publication Details

Journal
Journal of Basic and Environmental Sciences
Published
2024-10-01
DOI
https://doi.org/10.21608/jbes.2024.400810
Primary Topic
Surface Modification and Superhydrophobicity
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ablation of Polyester Capillaries by Electrothermal Pulsed Plasma Discharge

M. E. Abdel-kader, F. Diab, M. A. Abd Al-Halim, M. M. Abo El-Hadeed et al.
Journal of Basic and Environmental Sciences
Surface Modification and Superhydrophobicity
article

Ablation of Polyester Capillaries by Electrothermal Pulsed Plasma Discharge

M. E. Abdel-kader, F. Diab, M. A. Abd Al-Halim, M. M. Abo El-Hadeed, T. Y. Elrasasi
article en

Abstract

Plasma propulsion systems have become the most attractive systems for satellite engines due to their simplicity and reliability. This research was carried out to manufacture an electrothermal pulsed plasma thruster system using a polyester capillary. This study includes a measurement of ablated mass with different input voltage values and with increasing in the number of shots. It was found that by increasing the input voltage from 1.5 kV to 4 kV, the ablated mass increases from 120.6 µg to 432.6 µg. The experimental results were compared to the theoretical data obtained from the ETFLOW model; the calculated ablated mass increased from 136 µg to 447 µg, which is in good agreement with the measured results. Also, the model was used to study the behavior of some physical parameters with discharge time, such as plasma density, velocity, and temperature. Finally, the exit velocity was calculated as a function of peak current.

Journal of Basic and Environmental SciencesVol. 11(4)
Benha University (EG), Egyptian Atomic Energy Authority (EG)
Clean water and sanitation
Openalex Percentile: Top 76%
Surface Modification and Superhydrophobicity
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.