Mebeverine Hydrochloride Analysis in Pharmaceutical Manufacture using a Novel RP HPLC Method

For mebeverine (MBV) hydrochloride detection and quantification, a straightforward, sensitive, selective, dependable, fast, and high-performance liquid chromatographic approach was created. The ODS2-C18 column [4.6 mm × 150 mm particle] and reversed phase were employed in the procedure. Potassium dihydrogen phosphate (v/v) and 0.02 M acetonitrile (PH 3.6 30:70) made up the mobile phase, and the flow rate was 1.0 ml/min. A UV detector was utilized to measure the wavelength at 240 nm. The linear limits of the concentrations were between 1 and 100 μg/ml, the relative standard deviation was 3.2%, and the retention time of mebeverine was 1.03 minutes. The results acquired were in good agreement with the substance that was declared. Mebeverine hydrochloride can be quantitatively analyzed using the suggested method, which is rapid, accurate, and selective. The approach was proven to be precise, dependable, and accurate for the identification and measurement of (MBV) hydrochloride in formulations, bulk pharmaceuticals, and raw materials. For the measurement of mebeverine in both its pure and a variety of pharmaceutical sectors, the RP-HPLC method was straightforward, precise, linear, and quick.

Authors

Publication Details

Journal
Cognizance Journal of Multidisciplinary Studies
Published
2024-12-30
DOI
https://doi.org/10.47760/cognizance.2024.v04i12.051
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mebeverine Hydrochloride Analysis in Pharmaceutical Manufacture using a Novel RP HPLC Method

Nagham Hussein, Shatha Abd Al-Jabbar, Intisar Obaid Alfatlawi
Cognizance Journal of Multidisciplinary Studies
Analytical Methods in Pharmaceuticals
article

Mebeverine Hydrochloride Analysis in Pharmaceutical Manufacture using a Novel RP HPLC Method

Nagham Hussein, Shatha Abd Al-Jabbar, Intisar Obaid Alfatlawi
article en

Abstract

For mebeverine (MBV) hydrochloride detection and quantification, a straightforward, sensitive, selective, dependable, fast, and high-performance liquid chromatographic approach was created. The ODS2-C18 column [4.6 mm × 150 mm particle] and reversed phase were employed in the procedure. Potassium dihydrogen phosphate (v/v) and 0.02 M acetonitrile (PH 3.6 30:70) made up the mobile phase, and the flow rate was 1.0 ml/min. A UV detector was utilized to measure the wavelength at 240 nm. The linear limits of the concentrations were between 1 and 100 μg/ml, the relative standard deviation was 3.2%, and the retention time of mebeverine was 1.03 minutes. The results acquired were in good agreement with the substance that was declared. Mebeverine hydrochloride can be quantitatively analyzed using the suggested method, which is rapid, accurate, and selective. The approach was proven to be precise, dependable, and accurate for the identification and measurement of (MBV) hydrochloride in formulations, bulk pharmaceuticals, and raw materials. For the measurement of mebeverine in both its pure and a variety of pharmaceutical sectors, the RP-HPLC method was straightforward, precise, linear, and quick.

Cognizance Journal of Multidisciplinary StudiesVol. 4(12)
Clean water and sanitation
Openalex Percentile: Top 76%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.