Flexural Behavior of Reinforced Concrete Beams with Utility Facilities in the Section Area

Reinforced concrete beams that incorporate utility facilities are designed to enhance efficiency by reducing the overall volume of concrete required and providing a functional space for utility storage. The main objective of this study is to rigorously evaluate whether the load-bearing capacity of these specially designed beams is comparable to that of traditional solid-reinforced concrete beams. To achieve this, three beams were subjected to rigorous bending tests: one set of solid reinforced concrete beams and two sets that included utility facilities, utilizing 3-inch and 4-inch PVC pipes, respectively. The experimental results revealed that the bending capacity of each beam was primarily influenced by the allowable deflection, which was capped at 1.25 mm. The recorded bending capacities were as follows: 138.13 kN for the solid beams, 120.8 kN for the beams with 3-inch pipes, and 106.90 kN for those fitted with 4-inch pipes. These findings highlight a significant observation: the stiffness of the beams containing utility facilities—regardless of the pipe size—was notably lower than the solid reinforced concrete beams. However, these utility-equipped beams exhibited more excellent ductility, indicating they could undergo more deformation before failure. Additionally, the analysis of the relationship between load and deflection mirrored these trends, underscoring that the tensile strength of the reinforcement bars (rebar) plays a critical role in determining the bending capacity of the beams. This comprehensive evaluation provides valuable insights into the structural performance of reinforced concrete beams equipped with utility features, laying the groundwork for future construction practices prioritizing functionality and material efficiency.

Authors

Institutions

Publication Details

Journal
International Journal on Advanced Science Engineering and Information Technology
Published
2024-12-26
DOI
https://doi.org/10.18517/ijaseit.14.6.19243
Primary Topic
Civil and Structural Engineering Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Flexural Behavior of Reinforced Concrete Beams with Utility Facilities in the Section Area

Natsir Abduh, Arman Setiawan, Syahrul Sariman, Hasrullah Tulung
International Journal on Advanced Science Engineering and Information Technology
Civil and Structural Engineering Research
article

Flexural Behavior of Reinforced Concrete Beams with Utility Facilities in the Section Area

Natsir Abduh, Arman Setiawan, Syahrul Sariman, Hasrullah Tulung
article en

Abstract

Reinforced concrete beams that incorporate utility facilities are designed to enhance efficiency by reducing the overall volume of concrete required and providing a functional space for utility storage. The main objective of this study is to rigorously evaluate whether the load-bearing capacity of these specially designed beams is comparable to that of traditional solid-reinforced concrete beams. To achieve this, three beams were subjected to rigorous bending tests: one set of solid reinforced concrete beams and two sets that included utility facilities, utilizing 3-inch and 4-inch PVC pipes, respectively. The experimental results revealed that the bending capacity of each beam was primarily influenced by the allowable deflection, which was capped at 1.25 mm. The recorded bending capacities were as follows: 138.13 kN for the solid beams, 120.8 kN for the beams with 3-inch pipes, and 106.90 kN for those fitted with 4-inch pipes. These findings highlight a significant observation: the stiffness of the beams containing utility facilities—regardless of the pipe size—was notably lower than the solid reinforced concrete beams. However, these utility-equipped beams exhibited more excellent ductility, indicating they could undergo more deformation before failure. Additionally, the analysis of the relationship between load and deflection mirrored these trends, underscoring that the tensile strength of the reinforcement bars (rebar) plays a critical role in determining the bending capacity of the beams. This comprehensive evaluation provides valuable insights into the structural performance of reinforced concrete beams equipped with utility features, laying the groundwork for future construction practices prioritizing functionality and material efficiency.

International Journal on Advanced Science Engineering and Information TechnologyVol. 14(6)
Universitas Bosowa (ID)
Kementerian Pendidikan, Kebudayaan, Riset, dan Teknologi, Direktorat Jenderal Pendidikan Tinggi
Sustainable cities and communities
Openalex Percentile: Top 72%
Civil and Structural Engineering Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.