Magnetic Induction Phase Difference for Cerebral Hemorrhage Detection

Magnetic induction phase shift is a promising technology for the detection of cerebral hemorrhage, owing to its nonradioactive, noninvasive, and real-time detection properties. To enhance the detection sensitivity and linearity, a zero-flow sensor was proposed. The uniform primary magnetic field and its counteraction were achieved. Phase-change responses to solutions of varying conductivities and rabbits with cerebral hemorrhage were investigated and compared with traditional sensors. The sensitivities in detecting solutions with different conductivities were 1.84, 1.39, and 1.22 times higher than those for a low-pass birdcage coil, planar gradiometer, and Bx-sensor, respectively. The results for rabbits with cerebral hemorrhage showed that the sensitivities increased by 1.17, 1.67, and 6.3 times compared with a low-pass birdcage coil, symmetric cancelation-type sensor, and single co-axial coil, respectively. This sensor could accurately detect three stages in the pathological process. Blood loss of 1 mL meant that the compensatory mechanism of cerebrospinal fluid began to fail, and 1.4 mL of blood loss meant that the compensatory mechanism failed completely. The adjusted R-squared value of the first-order linear fit was above 0.98 in both physical and animal experiments, indicating that high detection linearity was achieved. The proposed sensor provides a more accurate method for cerebral hemorrhage detection and facilitates the practical application of magnetic induction phase shift in pre-hospital and bedside real-time detection.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2024-12-30
DOI
https://doi.org/10.3390/s25010157
Citations
1
Primary Topic
Atomic and Subatomic Physics Research
Type
article
Field-Weighted Citation Impact
0.34

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Magnetic Induction Phase Difference for Cerebral Hemorrhage Detection

Mingsheng Chen, Yan Lian, Hang Deng, Mingxin Qin et al.
1 citations
Sensors
Atomic and Subatomic Physics Research
0.34
article

Magnetic Induction Phase Difference for Cerebral Hemorrhage Detection

Mingsheng Chen, Yan Lian, Hang Deng, Mingxin Qin, Jie Liu
article en
1 citations

Abstract

Magnetic induction phase shift is a promising technology for the detection of cerebral hemorrhage, owing to its nonradioactive, noninvasive, and real-time detection properties. To enhance the detection sensitivity and linearity, a zero-flow sensor was proposed. The uniform primary magnetic field and its counteraction were achieved. Phase-change responses to solutions of varying conductivities and rabbits with cerebral hemorrhage were investigated and compared with traditional sensors. The sensitivities in detecting solutions with different conductivities were 1.84, 1.39, and 1.22 times higher than those for a low-pass birdcage coil, planar gradiometer, and Bx-sensor, respectively. The results for rabbits with cerebral hemorrhage showed that the sensitivities increased by 1.17, 1.67, and 6.3 times compared with a low-pass birdcage coil, symmetric cancelation-type sensor, and single co-axial coil, respectively. This sensor could accurately detect three stages in the pathological process. Blood loss of 1 mL meant that the compensatory mechanism of cerebrospinal fluid began to fail, and 1.4 mL of blood loss meant that the compensatory mechanism failed completely. The adjusted R-squared value of the first-order linear fit was above 0.98 in both physical and animal experiments, indicating that high detection linearity was achieved. The proposed sensor provides a more accurate method for cerebral hemorrhage detection and facilitates the practical application of magnetic induction phase shift in pre-hospital and bedside real-time detection.

SensorsVol. 25(1)
Army Medical University (CN), Xiamen University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 37%
Atomic and Subatomic Physics Research
0.34
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.