Finite Element Analysis of T-Shaped Concrete-Filled Steel Tubular Short Columns with Stiffening Ribs Under Axial Compression

A new type of stiffening rib is proposed to improve the mechanical performance of T-shaped concrete-filled steel tubular (CFST) columns. A finite element model was established using the general-purpose commercial software ABAQUS 2022. After verification through comparison with experimental data, the developed finite element model was employed to numerically evaluate the performance of T-shaped CFST short columns with stiffening ribs under axial compression. The results indicated that the new stiffening ribs are capable of significantly reducing the buckling deformation of the steel tube, enhancing the confinement effect of the steel tube on the core concrete, and improving the combined performance of the steel tube and the concrete. The thickness and material strength of the stiffening ribs had a notable impact on the ultimate bearing capacity and ductility of the short column specimens. When the thickness of the stiffening ribs increased from 5 mm to 8 mm, the ultimate bearing capacity correspondingly increased by 10.51% to 31.77%, while the ductility coefficient improved by 6.48% to 17.20%. When the steel strength increased from 262.50 MPa to 345 MPa and 390 MPa, the ultimate bearing capacity correspondingly increased by 17.36%, 19.78%, and 30.50%, and the ductility coefficient improved by 12%, 13.87% and 23.92%. The changes in the specifications and arrangement of the stiffening ribs had no significant effect on the ultimate bearing capacity and ductility of the specimens. The change in angle steel specifications caused variations in ultimate bearing capacity within ±5% and variations in the ductility coefficient within ±10%. Changes in the arrangement caused variations in ultimate bearing capacity within ±1% and variations in the ductility coefficient within ±5%.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2024-12-31
DOI
https://doi.org/10.3390/buildings15010112
Citations
4
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
1.04

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Finite Element Analysis of T-Shaped Concrete-Filled Steel Tubular Short Columns with Stiffening Ribs Under Axial Compression

Guoyang Fu, A.K.M. Mizanur Rahman, Xiaosan Yin, Yuzhou Sun et al.
4 citations
Buildings
Structural Load-Bearing Analysis
1.04
article

Finite Element Analysis of T-Shaped Concrete-Filled Steel Tubular Short Columns with Stiffening Ribs Under Axial Compression

Guoyang Fu, A.K.M. Mizanur Rahman, Xiaosan Yin, Yuzhou Sun, Honghao Yue, Jimin Li
article en
4 citations

Abstract

A new type of stiffening rib is proposed to improve the mechanical performance of T-shaped concrete-filled steel tubular (CFST) columns. A finite element model was established using the general-purpose commercial software ABAQUS 2022. After verification through comparison with experimental data, the developed finite element model was employed to numerically evaluate the performance of T-shaped CFST short columns with stiffening ribs under axial compression. The results indicated that the new stiffening ribs are capable of significantly reducing the buckling deformation of the steel tube, enhancing the confinement effect of the steel tube on the core concrete, and improving the combined performance of the steel tube and the concrete. The thickness and material strength of the stiffening ribs had a notable impact on the ultimate bearing capacity and ductility of the short column specimens. When the thickness of the stiffening ribs increased from 5 mm to 8 mm, the ultimate bearing capacity correspondingly increased by 10.51% to 31.77%, while the ductility coefficient improved by 6.48% to 17.20%. When the steel strength increased from 262.50 MPa to 345 MPa and 390 MPa, the ultimate bearing capacity correspondingly increased by 17.36%, 19.78%, and 30.50%, and the ductility coefficient improved by 12%, 13.87% and 23.92%. The changes in the specifications and arrangement of the stiffening ribs had no significant effect on the ultimate bearing capacity and ductility of the specimens. The change in angle steel specifications caused variations in ultimate bearing capacity within ±5% and variations in the ductility coefficient within ±10%. Changes in the arrangement caused variations in ultimate bearing capacity within ±1% and variations in the ductility coefficient within ±5%.

BuildingsVol. 15(1)
Zhongyuan University of Technology (CN), Southern Cross University (AU)
Natural Science Foundation of Hainan Province, Natural Science Foundation of Henan Province
Openalex Percentile: Top 24%
Structural Load-Bearing Analysis
1.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.