Millisecond-level transient heating and temperature monitoring technique for ultrasound-induced thermal strain imaging
<b>Background:</b> Ultrasound-induced thermal strain imaging (US-TSI) is a promising ultrasound imaging modality that has been demonstrated in preclinical studies to identify a lipid-rich necrotic core of an atherosclerotic plaque. However, human physiological motion, e.g., cardiac pulsation, poses challenges in implementing US-TSI applications, where achieving a millisecond-level temperature rise by delivering acoustic energy from a compact US-TSI probe is a key requirement. This study aims to develop a transient ultrasound heating and thermocouple monitoring technique at the millisecond level for US-TSI applications. <b>Methods:</b> We designed, prototyped, and characterized a novel US-TSI probe that includes a high-power, 3.5 MHz heating transducer with symmetrical dual 1D concave array. Additionally, millisecond-level temperature monitoring was demonstrated with fast-response thermocouples in laser- and ultrasound- induced thermal tests. Subsequently, we demonstrated the prototyped US-TSI probe can produce a desired temperature rise in a millisecond-short time window <i>in vitro</i> phantom and <i>in vivo</i> animal tests. <b>Results:</b> The prototyped US-TSI probe delivered zero-to-peak acoustic pressure up to 6.2 MPa with a 90 V<sub>PP</sub> input voltage. Both laser- and ultrasound- induced thermal tests verified that the selected thermocouples can monitor temperature change within 50 ms. The fast-response thermocouple confirmed the transient heating ability of the US-TSI probe, achieving a 3.9 °C temperature rise after a 25 ms heating duration (50% duty cycle) in the gel phantom and a 2.0 °C temperature rise after a 50 ms heating duration (50% duty cycle) in a pig model. <b>Conclusions:</b> We successfully demonstrated a millisecond-level transient heating and temperature monitoring technique utilizing the novel US-TSI probe and fast-response thermocouples. The reported transient ultrasound heating and thermocouple monitoring technique is promising for future <i>in vivo</i> human subject studies in US-TSI or other ultrasound-related thermal investigations.
Authors
- Mengyue Chen (ORCID: https://orcid.org/0000-0002-6482-5381)
- Bohua Zhang (ORCID: https://orcid.org/0000-0002-9329-0507)
- Xiaoning Jiang (ORCID: https://orcid.org/0000-0003-3605-3801)
- Ran Wei (ORCID: https://orcid.org/0000-0003-0586-5233)
- Yu Chu (ORCID: https://orcid.org/0000-0003-0930-4628)
- Howuk Kim (ORCID: https://orcid.org/0000-0002-4878-0486)
- Huaiyu Wu (ORCID: https://orcid.org/0000-0003-2616-1171)
- Dhanansayan Shanmuganayagam (ORCID: https://orcid.org/0000-0002-8882-1668)
- Zhiyu Sheng (ORCID: https://orcid.org/0000-0002-4209-5939)
- A. B. Breon
- Matthew B. Wielgat
- Sibo Li (ORCID: https://orcid.org/0000-0003-3742-4694)
- Kang Kim (ORCID: https://orcid.org/0000-0003-1966-1135)
- Qiyang Chen (ORCID: https://orcid.org/0000-0002-9509-6740)
- Edith Tzeng
- Xuecang Geng
Institutions
- University of Wisconsin System (US)
- University of Wisconsin–Madison (US)
- North Carolina State University (US)
- University of Pittsburgh (US)
- Inha University (KR)
- Blatek (United States) (US)
- U.S. Dairy Forage Research Center (US)
- Medical Technologies (Czechia) (CZ)
Publication Details
- Journal
- Theranostics
- Published
- 2024-12-31
- DOI
- https://doi.org/10.7150/thno.95997
- Citations
- 5
- Primary Topic
- Thermography and Photoacoustic Techniques
- Type
- article
- Field-Weighted Citation Impact
- 1.35
Funders
- National Institutes of Health