Development and Validation of a Stability‐Indicating High‐Performance Liquid Chromatography Method Coupled With a Diode Array Detector for Quantifying Haloperidol in Oral Solution Using the Analytical Quality‐by‐Design Approach

This study developed a stability-indicating HPLC-DAD method for quantifying haloperidol in oral solution using analytical quality-by-design principles. Haloperidol stability was tested under acidic, alkaline, oxidative, and photolytic stress conditions. The analytical quality-by-design approach began by defining the analytical target profile and identifying critical material attributes and critical method parameters via risk analysis. Factorial and Box-Behnken designs, conducted in Design Expert 13, were used to select critical method parameters and determine the method operable design region. The oral solution degraded significantly under acidic and alkaline conditions. Continuous critical method parameters such as mobile phase flow rate, gradient slope, column temperature, and pH were optimized. A quadratic Box-Behnken design with critical method attributes was applied and validated, resulting in robust regression models with significant p-values (> 0.05), absence of lack-of-fit (p-values < 0.05), and R<sup>2</sup>-adjusted > 0.85. The method proved selective, accurate, and precise within the method operable design range. Normal operating conditions (NOCs) were established using a Waters Symmetry C18 column with a 100-mM formate buffer (pH 3.8) and acetonitrile, with a gradient profile and detection at 246 nm. The operational region included flow rates between 1.2 and 1.35 mL/min (NOC = 1.3 mL/min), temperatures of 8°C-20°C (NOC = 15°C), and mobile phase pH variations from 3.3 to 4.3 (NOC = 3.8). The analytical quality-by-design-based method was robust and effective for stability monitoring, reducing subjectivity while maximizing reliability.

Authors

Institutions

Publication Details

Journal
Journal of Separation Science
Published
2024-12-30
DOI
https://doi.org/10.1002/jssc.70067
Citations
10
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
2.36

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Validation of a Stability‐Indicating High‐Performance Liquid Chromatography Method Coupled With a Diode Array Detector for Quantifying Haloperidol in Oral Solution Using the Analytical Quality‐by‐Design Approach

Roberto Pontarolo, Luana Mota Ferreira, Karime Zeraik Abdalla Domingues, Allan Michael Junkert et al.
10 citations
Journal of Separation Science
Analytical Methods in Pharmaceuticals
2.36
article

Development and Validation of a Stability‐Indicating High‐Performance Liquid Chromatography Method Coupled With a Diode Array Detector for Quantifying Haloperidol in Oral Solution Using the Analytical Quality‐by‐Design Approach

Roberto Pontarolo, Luana Mota Ferreira, Karime Zeraik Abdalla Domingues, Allan Michael Junkert, Naomi Gerzvolf Mieres
article en
10 citations

Abstract

This study developed a stability-indicating HPLC-DAD method for quantifying haloperidol in oral solution using analytical quality-by-design principles. Haloperidol stability was tested under acidic, alkaline, oxidative, and photolytic stress conditions. The analytical quality-by-design approach began by defining the analytical target profile and identifying critical material attributes and critical method parameters via risk analysis. Factorial and Box-Behnken designs, conducted in Design Expert 13, were used to select critical method parameters and determine the method operable design region. The oral solution degraded significantly under acidic and alkaline conditions. Continuous critical method parameters such as mobile phase flow rate, gradient slope, column temperature, and pH were optimized. A quadratic Box-Behnken design with critical method attributes was applied and validated, resulting in robust regression models with significant p-values (> 0.05), absence of lack-of-fit (p-values < 0.05), and R<sup>2</sup>-adjusted > 0.85. The method proved selective, accurate, and precise within the method operable design range. Normal operating conditions (NOCs) were established using a Waters Symmetry C18 column with a 100-mM formate buffer (pH 3.8) and acetonitrile, with a gradient profile and detection at 246 nm. The operational region included flow rates between 1.2 and 1.35 mL/min (NOC = 1.3 mL/min), temperatures of 8°C-20°C (NOC = 15°C), and mobile phase pH variations from 3.3 to 4.3 (NOC = 3.8). The analytical quality-by-design-based method was robust and effective for stability monitoring, reducing subjectivity while maximizing reliability.

Journal of Separation ScienceVol. 48(1)
Universidade Federal do Paraná (BR)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, Conselho Nacional de Desenvolvimento Científico e Tecnológico
Clean water and sanitation
Openalex Percentile: Top 12%
Analytical Methods in Pharmaceuticals
2.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.