Evaluasi Unjuk Kerja Boiler: Studi Kasus pada Pabrik Pulp dan Kertas PT. ABC

In process industries or power generation, boilers are one of the first components to consume energy. Moreover, poor combustion, heat transfer fouling, and improper operation and maintenance lead to a gradual decrease in efficiency. In addition, poor fuel and water quality cause boiler performance to decrease. As a result, efficiency testing helps determine how far the boiler efficiency deviates from the best efficiency level. A complete energy audit of the boiler was conducted at PT. ABC Pulp and Paper Mill with ASME (American Society for Mechanical Engineers) power test code, PTC 4.1. Direct method is an input-output method, and Indirect mehod is a method of heat loss that occurs in the boiler. The direct method shows an efficiency of 84.46% and the indirect method shows an efficiency of 78.73%. Based on direct and indirect methods showing a difference of 5.73%, it is reported that the total heat loss is 21.26% where the highest is in the dry flue gas of 14.88%, namely the incoming heat energy is carried away with dry flue gas.

Authors

Institutions

Publication Details

Journal
Turbo Jurnal Program Studi Teknik Mesin
Published
2024-11-30
DOI
https://doi.org/10.24127/trb.v13i2.3119
Primary Topic
Management and Optimization Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluasi Unjuk Kerja Boiler: Studi Kasus pada Pabrik Pulp dan Kertas PT. ABC

Awaludin Martin, Nur Khotimah, Fikri Fahlevi Nasution, Tikkos Sihombing
Turbo Jurnal Program Studi Teknik Mesin
Management and Optimization Techniques
article

Evaluasi Unjuk Kerja Boiler: Studi Kasus pada Pabrik Pulp dan Kertas PT. ABC

Awaludin Martin, Nur Khotimah, Fikri Fahlevi Nasution, Tikkos Sihombing
article en

Abstract

In process industries or power generation, boilers are one of the first components to consume energy. Moreover, poor combustion, heat transfer fouling, and improper operation and maintenance lead to a gradual decrease in efficiency. In addition, poor fuel and water quality cause boiler performance to decrease. As a result, efficiency testing helps determine how far the boiler efficiency deviates from the best efficiency level. A complete energy audit of the boiler was conducted at PT. ABC Pulp and Paper Mill with ASME (American Society for Mechanical Engineers) power test code, PTC 4.1. Direct method is an input-output method, and Indirect mehod is a method of heat loss that occurs in the boiler. The direct method shows an efficiency of 84.46% and the indirect method shows an efficiency of 78.73%. Based on direct and indirect methods showing a difference of 5.73%, it is reported that the total heat loss is 21.26% where the highest is in the dry flue gas of 14.88%, namely the incoming heat energy is carried away with dry flue gas.

Turbo Jurnal Program Studi Teknik MesinVol. 13(2)
Riau University (ID)
Openalex Percentile: Top 57%
Management and Optimization Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluasi Unjuk Kerja Boiler: Studi Kasus pada Pabrik Pulp dan Kertas PT. ABC — Awaludin Martin, Nur Khotimah, et al. · Turbo Jurnal Program Studi Teknik Mesin (2024) | TGRS Research Map | TGRS