Iloprost‐Loaded Electrospun Polycaprolactone/Gelatin Membranes for Enhanced Healing of Colon Anastomosis

Despite the variety of proposed solutions, anastomotic leakage is still a critical complication after colorectal surgery, which causes increased clinical mortality and morbidity. By enhancing microcirculation in the colonic mucosa, the use of Iloprost (Ilo) has shown promising results for the healing of anastomosis. The purpose of this study is to examine the performance of Ilo-impregnated Polycaprolactone:Gelatin electrospun membranes (PCL/Gel/Ilo) on anastomosis repair and intra-abdominal adhesion behavior in the Rat colon. Wistar Albino rats were randomly divided into four groups: sham, Control (only resection-anastomosis), PCL/Gel, and PCL/Gel /Ilo (n = 12 for each). On the seventh day after colon anastomosis, a second laparotomy was conducted. During this procedure, intra-abdominal adhesion was examined, and the anastomotic segment was removed for burst pressure and histological evaluation. There was no statistically significant difference in intra-abdominal adhesions and major complications between the electrospun membrane groups and the control group. The membrane-applied groups exhibited significantly higher anastomotic burst pressure than the control group irrespective of their Ilo content. In terms of neovascularization and muscle necrosis, membrane-applied groups demonstrated statistically significant improvements over the control group. Furthermore, the PCL/Gel/Ilo applied group showed enhanced neovascularization and lower muscular necrosis; however, statistically significant differences were not observed compared to the PCL/Gel applied group. Compared to the control group, the application of electrospun PCL/Gel and PCL/Gel/Ilo membranes resulted in safe and effective healing of colon anastomosis. The fact that Ilo application cannot be distinguished from the regular membrane group necessitates additional research into the doped fibrous mat and its application method.

Authors

Publication Details

Journal
Journal of Biomedical Materials Research Part B Applied Biomaterials
Published
2024-12-30
DOI
https://doi.org/10.1002/jbm.b.35518
Primary Topic
Electrospun Nanofibers in Biomedical Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Iloprost‐Loaded Electrospun Polycaprolactone/Gelatin Membranes for Enhanced Healing of Colon Anastomosis

Sema Hücümenoğlu, Pinar Eylem Eser, Fatih Büyükserin, Ender ERGÜDER et al.
Journal of Biomedical Materials Research Part B Applied Biomaterials
Electrospun Nanofibers in Biomedical Applications
article

Iloprost‐Loaded Electrospun Polycaprolactone/Gelatin Membranes for Enhanced Healing of Colon Anastomosis

Sema Hücümenoğlu, Pinar Eylem Eser, Fatih Büyükserin, Ender ERGÜDER, Abdullah DURHAN, Merve Celik, Mehmet Ali Akkuş
article en

Abstract

Despite the variety of proposed solutions, anastomotic leakage is still a critical complication after colorectal surgery, which causes increased clinical mortality and morbidity. By enhancing microcirculation in the colonic mucosa, the use of Iloprost (Ilo) has shown promising results for the healing of anastomosis. The purpose of this study is to examine the performance of Ilo-impregnated Polycaprolactone:Gelatin electrospun membranes (PCL/Gel/Ilo) on anastomosis repair and intra-abdominal adhesion behavior in the Rat colon. Wistar Albino rats were randomly divided into four groups: sham, Control (only resection-anastomosis), PCL/Gel, and PCL/Gel /Ilo (n = 12 for each). On the seventh day after colon anastomosis, a second laparotomy was conducted. During this procedure, intra-abdominal adhesion was examined, and the anastomotic segment was removed for burst pressure and histological evaluation. There was no statistically significant difference in intra-abdominal adhesions and major complications between the electrospun membrane groups and the control group. The membrane-applied groups exhibited significantly higher anastomotic burst pressure than the control group irrespective of their Ilo content. In terms of neovascularization and muscle necrosis, membrane-applied groups demonstrated statistically significant improvements over the control group. Furthermore, the PCL/Gel/Ilo applied group showed enhanced neovascularization and lower muscular necrosis; however, statistically significant differences were not observed compared to the PCL/Gel applied group. Compared to the control group, the application of electrospun PCL/Gel and PCL/Gel/Ilo membranes resulted in safe and effective healing of colon anastomosis. The fact that Ilo application cannot be distinguished from the regular membrane group necessitates additional research into the doped fibrous mat and its application method.

Journal of Biomedical Materials Research Part B Applied BiomaterialsVol. 113(1)
Good health and well-being
Openalex Percentile: Top 88%
Electrospun Nanofibers in Biomedical Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.