Contact Lens Discomfort (CLD) Treatment with MY MASK Light Modulation® LED mask

The purpose of this study was to understand how the use of the light modulation LED mask MY MASK affects Contact Lens Discomfort (CLD). Forty-two (42) soft contact lens wearers with dry eye symptoms were recruited for a 3-week descriptive observational study. Treatment using the light modulation LED mask was applied three times, each lasting 15 minutes; on day 1, day 3 and after one week. Symptoms of CLD were quantified with the help of a specific questionnaire (CLDEQ-8) before and after treatment. Ocular surface and tear film measurements were conducted at baseline and 1 week after the last treatment. Visual acuity remained stable (0.00 LogMAR ± 0.10). The number of symptomatic contact lens wearers decreased by 43% (18 out of 42 subjects), as indicated by the CLDEQ-8 scores (t−test=5.14; p < 0.001) (R2=0.218). Non-invasive tear film breakup time (NIBUT) improved significantly. Before treatment, 70% of eyes (59 out of 84) showed a NIBUT of less than 10 s; after treatment, 26% had values below this cut-off (t-test=3.06; p=0.001) (R2=0.241). Meibography values did not change (t-test= 1.17; p= 0.121) (R2 = 0.872). TearScope showed considerable improvement in tear film lipid layer thickness and the data obtained through the Gland Evaluator also demonstrated an improvement. Treatment using light modulation LED mask could be an interesting option in improving the aspects that characterise CLD. Additional research is required to establish the reliability of the observed improvement and investigate the necessity of repeated treatments as a means of stabilising or sustaining satisfaction in contact lens wearers.

Authors

Institutions

Publication Details

Journal
Scandinavian Journal of Optometry and Visual Science
Published
2024-12-31
DOI
https://doi.org/10.15626/sjovs.v17i2.4212
Citations
3
Primary Topic
Ocular Surface and Contact Lens
Type
article
Field-Weighted Citation Impact
1.63
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Contact Lens Discomfort (CLD) Treatment with MY MASK Light Modulation® LED mask

Pietro Gheller, L. Stančo, David P. Piñero, Enrico Pavan Michielon
3 citations
Scandinavian Journal of Optometry and Visual Science
Ocular Surface and Contact Lens
1.63
article

Contact Lens Discomfort (CLD) Treatment with MY MASK Light Modulation® LED mask

Pietro Gheller, L. Stančo, David P. Piñero, Enrico Pavan Michielon
article en
3 citations

Abstract

The purpose of this study was to understand how the use of the light modulation LED mask MY MASK affects Contact Lens Discomfort (CLD). Forty-two (42) soft contact lens wearers with dry eye symptoms were recruited for a 3-week descriptive observational study. Treatment using the light modulation LED mask was applied three times, each lasting 15 minutes; on day 1, day 3 and after one week. Symptoms of CLD were quantified with the help of a specific questionnaire (CLDEQ-8) before and after treatment. Ocular surface and tear film measurements were conducted at baseline and 1 week after the last treatment. Visual acuity remained stable (0.00 LogMAR ± 0.10). The number of symptomatic contact lens wearers decreased by 43% (18 out of 42 subjects), as indicated by the CLDEQ-8 scores (t−test=5.14; p < 0.001) (R2=0.218). Non-invasive tear film breakup time (NIBUT) improved significantly. Before treatment, 70% of eyes (59 out of 84) showed a NIBUT of less than 10 s; after treatment, 26% had values below this cut-off (t-test=3.06; p=0.001) (R2=0.241). Meibography values did not change (t-test= 1.17; p= 0.121) (R2 = 0.872). TearScope showed considerable improvement in tear film lipid layer thickness and the data obtained through the Gland Evaluator also demonstrated an improvement. Treatment using light modulation LED mask could be an interesting option in improving the aspects that characterise CLD. Additional research is required to establish the reliability of the observed improvement and investigate the necessity of repeated treatments as a means of stabilising or sustaining satisfaction in contact lens wearers.

Scandinavian Journal of Optometry and Visual ScienceVol. 17(2)
University of Padua (IT)
Good health and well-being
Openalex Percentile: Top 14%
Ocular Surface and Contact Lens
1.63
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Contact Lens Discomfort (CLD) Treatment with MY MASK Light Modulation® LED mask — Pietro Gheller, L. Stančo, et al. · Scandinavian Journal of Optometry and Visual Science (2024) | TGRS Research Map | TGRS