Comparison of ZnS(Ag) Scintillator and Proportional Counter Tube for Alpha Detection in Thin-Layer Chromatography
(1) <b>Background</b>: Targeted alpha therapy is an emerging field in nuclear medicine driven by two advantages: overcoming resistance in cancer-suffering patients to beta therapies and the practical application of lower activities of <sup>212</sup>Pb- and <sup>225</sup>Ac-labelled peptides to achieve the same doses compared to beta therapy due to the highly cytotoxic nature of alpha particles. However, quality control of the <sup>212</sup>Pb/<sup>225</sup>Ac-radiopharmaceuticals remains a challenge due to the low activity levels used for therapy (100 kBq/kg) and the formation of several free daughter nuclides immediately after the formulation of patient doses; (2) <b>Methods</b>: The routine alpha detection on thin-layer chromatograms (TLC) of <sup>212</sup>Pb- and <sup>225</sup>Ac-labelled peptides using a MiniScanPRO+ scanner combined with an alpha detector head was compared with detection using an AR-2000 scanner equipped with an open proportional counter tube. Measurement time, resolution and validity were compared for both scanners; (3) <b>Results</b>: For <sup>225</sup>Ac, the quality control values of the radiochemical purity (RCP) were within the acceptance criteria 2 h after TLC development, regardless of when the TLC probe was taken. That is, if the TLC probe was taken 24 h after radiosynthesis, the true value of the RCP was not measured until 5 h after TLC development. For <sup>212</sup>Pb-labelled peptides, the probe sampling did not have a high impact on the value of the RCP for the MiniScanPRO+ and AR-2000. A difference was observed when measuring TLC with the AR-2000 in different modes; (4) <b>Conclusions</b>: The MiniScanPRO+ is fast, does not require additional equipment and can also measure the gamma spectrum, which may be important for some radiopharmaceutical production sites and regulatory authorities. The AR-2000 has a better signal-to-noise ratio, and this eliminates the need for additional waiting time after TLC development.
Authors
- Ralph A. Bundschuh (ORCID: https://orcid.org/0000-0001-7291-9372)
- Enrico Michler (ORCID: https://orcid.org/0000-0002-4404-0114)
- Marc Pretze (ORCID: https://orcid.org/0000-0002-6432-5694)
- Robert Freudenberg (ORCID: https://orcid.org/0000-0002-1970-6957)
- Holger Hartmann
- Jörg Kotzerke
- Jan Wendrich
Institutions
- University Hospital Carl Gustav Carus (DE)
Publication Details
- Journal
- Pharmaceuticals
- Published
- 2024-12-28
- DOI
- https://doi.org/10.3390/ph18010026
- Citations
- 2
- Primary Topic
- Radiopharmaceutical Chemistry and Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.81