Development of matrix reference material for reliable phenthoate determination in mango by gas chromatography-nitrogen phosphorus detector (GC-NPD) and gas chromatography tandem mass spectrometry (GC-MS/MS)

Organophosphate pesticides, like phenthoate, are essential for agricultural production and pest control, but excessive levels can be harmful. Pesticide residue analysis in food requires matrix reference materials (RMs), which are scarce for all pesticide-matrix combinations. This study developed an RM for detecting phenthoate residues in mangoes. The material was lyophilized, fortified with phenthoate, homogenized, and characterized. Homogeneity and stability were assessed using Gas Chromatography with Nitrogen-Phosphorus Detector (GC-NPD) following ISO Guide 35:2017. Linear regression and Cochran's Test found no significant trends or outliers. ANOVA confirmed the homogeneity of the prepared RM, with a standard uncertainty ( u bb ) of 3.24 %. The RM remained stable at 4 °C for three weeks and at −20 °C for six months, with a standard uncertainty ( u lts ) of 7.09 %. GC-MS/MS quantified the reference value as 15.69 ± 4.0 μg/kg (n = 6) at a 95 % confidence level (k = 2). This RM aids in quality control and method validation for phenthoate detection in mangoes.

Authors

Institutions

Publication Details

Journal
Measurement Sensors
Published
2024-12-31
DOI
https://doi.org/10.1016/j.measen.2024.101768
Primary Topic
Plant Physiology and Cultivation Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of matrix reference material for reliable phenthoate determination in mango by gas chromatography-nitrogen phosphorus detector (GC-NPD) and gas chromatography tandem mass spectrometry (GC-MS/MS)

Benilda S. Ebarvia, Aaron C. Dacuya, Johanna Andrea Valdueza, Alleni T. Junsay et al.
Measurement Sensors
Plant Physiology and Cultivation Studies
article

Development of matrix reference material for reliable phenthoate determination in mango by gas chromatography-nitrogen phosphorus detector (GC-NPD) and gas chromatography tandem mass spectrometry (GC-MS/MS)

Benilda S. Ebarvia, Aaron C. Dacuya, Johanna Andrea Valdueza, Alleni T. Junsay, Abigail Grace H. Bion, Jomar C. Sta Ana
article en

Abstract

Organophosphate pesticides, like phenthoate, are essential for agricultural production and pest control, but excessive levels can be harmful. Pesticide residue analysis in food requires matrix reference materials (RMs), which are scarce for all pesticide-matrix combinations. This study developed an RM for detecting phenthoate residues in mangoes. The material was lyophilized, fortified with phenthoate, homogenized, and characterized. Homogeneity and stability were assessed using Gas Chromatography with Nitrogen-Phosphorus Detector (GC-NPD) following ISO Guide 35:2017. Linear regression and Cochran's Test found no significant trends or outliers. ANOVA confirmed the homogeneity of the prepared RM, with a standard uncertainty ( u bb ) of 3.24 %. The RM remained stable at 4 °C for three weeks and at −20 °C for six months, with a standard uncertainty ( u lts ) of 7.09 %. GC-MS/MS quantified the reference value as 15.69 ± 4.0 μg/kg (n = 6) at a 95 % confidence level (k = 2). This RM aids in quality control and method validation for phenthoate detection in mangoes.

Measurement SensorsVol. 38
Department of Science and Technology (PH)
Openalex Percentile: Top 86%
Plant Physiology and Cultivation Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Development of matrix reference material for reliable phenthoate determination in mango by gas chromatography-nitrogen phosphorus detector (GC-NPD) and gas chromatography tandem mass spectrometry (GC-MS/MS) — Benilda S. Ebarvia, Aaron C. Dacuya, et al. · Measurement Sensors (2024) | TGRS Research Map | TGRS