Resolution adjustable TDLAS tomography of axisymmetric flame temperature by using a single photodiode

A resolution adjustable TDLAS tomography method was proposed for axisymmetric flame imaging, and it has the merits of compactness and mechanical scanning-free. Two lasers at different wavelengths were broadened to be line light sources to pass through the flame and received by a single pixel detector after modulated by digital micro-mirror device. The distribution of integrated absorbance in different paths are reconstructed from the detector by a single pixel imaging method. Temperature distributions of axisymmetric flame are retrieved by using inverse Abel transform. Different imaging resolutions can be achieved adjustably and no hardware modifications is required. The efficacy of the proposed method was verified through simulations and experiments, and the reconstructed temperature images of axisymmetric flames are achieved as 23 × 23 and 47 × 47 resolutions for different resolutions.

Authors

Institutions

Publication Details

Journal
Measurement Sensors
Published
2024-12-31
DOI
https://doi.org/10.1016/j.measen.2024.101637
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Resolution adjustable TDLAS tomography of axisymmetric flame temperature by using a single photodiode

Guangyu Hou, Lijun Xu, Zhang Cao, Hui Gao et al.
Measurement Sensors
Spectroscopy and Laser Applications
article

Resolution adjustable TDLAS tomography of axisymmetric flame temperature by using a single photodiode

Guangyu Hou, Lijun Xu, Zhang Cao, Hui Gao, Wanpeng Zhang
article en

Abstract

A resolution adjustable TDLAS tomography method was proposed for axisymmetric flame imaging, and it has the merits of compactness and mechanical scanning-free. Two lasers at different wavelengths were broadened to be line light sources to pass through the flame and received by a single pixel detector after modulated by digital micro-mirror device. The distribution of integrated absorbance in different paths are reconstructed from the detector by a single pixel imaging method. Temperature distributions of axisymmetric flame are retrieved by using inverse Abel transform. Different imaging resolutions can be achieved adjustably and no hardware modifications is required. The efficacy of the proposed method was verified through simulations and experiments, and the reconstructed temperature images of axisymmetric flames are achieved as 23 × 23 and 47 × 47 resolutions for different resolutions.

Measurement SensorsVol. 38
Beijing Aerospace Flight Control Center (CN), Beihang University (CN)
Affordable and clean energy
Openalex Percentile: Top 81%
Spectroscopy and Laser Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Resolution adjustable TDLAS tomography of axisymmetric flame temperature by using a single photodiode — Guangyu Hou, Lijun Xu, et al. · Measurement Sensors (2024) | TGRS Research Map | TGRS