Normalization of Retinal Birefringence Scanning Signals

Signal amplitudes obtained from retinal scanning depend on numerous factors. Working with polarized light to interrogate the retina, large parts of which are birefringent, is even more prone to artifacts. This article demonstrates the necessity of using normalization when working with retinal birefringence scanning signals in polarization-sensitive ophthalmic instruments. After discussing the pros and cons of employing a normalization signal obtained by means of added optoelectronic hardware, the study shifts over and focuses on a numerical normalization method based on merely the <i>s</i>- and <i>p</i>-polarization components without additional optical or electronic hardware. This minimizes the adverse effects of optical asymmetries, the presence of certain instrumental noise, device-to-device variability, pupil diameter, retinal reflectivity, subject-to-subject variations, the position of the eye in the exit pupil of the device, and even signal degradation by cataracts. Results were experimentally and numerically tested on human data from 15 test subjects and clearly demonstrated the signal standardization achieved by numerical normalization. This is expected to lead to substantial improvement in algorithms and decision-making software, especially in ophthalmic screening instruments for pediatric applications, without added hardware cost. The proposed normalization method is also applicable to other polarization-sensitive optical instruments.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2024-12-31
DOI
https://doi.org/10.3390/s25010165
Primary Topic
Retinal Imaging and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Normalization of Retinal Birefringence Scanning Signals

Boris I. Gramatikov, David L. Guyton
Sensors
Retinal Imaging and Analysis
article

Normalization of Retinal Birefringence Scanning Signals

Boris I. Gramatikov, David L. Guyton
article en

Abstract

Signal amplitudes obtained from retinal scanning depend on numerous factors. Working with polarized light to interrogate the retina, large parts of which are birefringent, is even more prone to artifacts. This article demonstrates the necessity of using normalization when working with retinal birefringence scanning signals in polarization-sensitive ophthalmic instruments. After discussing the pros and cons of employing a normalization signal obtained by means of added optoelectronic hardware, the study shifts over and focuses on a numerical normalization method based on merely the <i>s</i>- and <i>p</i>-polarization components without additional optical or electronic hardware. This minimizes the adverse effects of optical asymmetries, the presence of certain instrumental noise, device-to-device variability, pupil diameter, retinal reflectivity, subject-to-subject variations, the position of the eye in the exit pupil of the device, and even signal degradation by cataracts. Results were experimentally and numerically tested on human data from 15 test subjects and clearly demonstrated the signal standardization achieved by numerical normalization. This is expected to lead to substantial improvement in algorithms and decision-making software, especially in ophthalmic screening instruments for pediatric applications, without added hardware cost. The proposed normalization method is also applicable to other polarization-sensitive optical instruments.

SensorsVol. 25(1)
Johns Hopkins University (US), Johns Hopkins Medicine (US)
Peace, Justice and strong institutions
Openalex Percentile: Top 58%
Retinal Imaging and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Normalization of Retinal Birefringence Scanning Signals — Boris I. Gramatikov, David L. Guyton · Sensors (2024) | TGRS Research Map | TGRS