Air Conditioning Load Monitoring in NILM Using Low Frequency Power Data

Air conditioning loads are typically flexible loads and contribute significantly to enhancing energy efficiency while optimizing the operation of the electrical grid. However, air conditioners themselves are continuously variable loads, and accurately monitoring their load status is a challenging task in the field of non-intrusive load monitoring. To solve this problem, this paper proposes a template matching-based load monitoring method for air conditioners. First, this paper presents a load event detection strategy designed to identify changes in appliance operational status; subsequently, for each load event, multidimensional load features are extracted; finally, the extracted load features are fused, and in this way, an air conditioning load recognition model is constructed and trained to realize the air conditioning load state recognition. Tests comparing the proposed method with existing ones, using both the REDD dataset and real-world data collected in Henan, China, demonstrate that the proposed method can accurately monitor the air conditioning load status.

Authors

Institutions

Publication Details

Published
2024-10-25
DOI
https://doi.org/10.1109/acfpe63443.2024.10801151
Citations
3
Primary Topic
Sensor Technology and Measurement Systems
Type
article
Field-Weighted Citation Impact
1.05

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Air Conditioning Load Monitoring in NILM Using Low Frequency Power Data

Minzhe Tian, Letian Guo, Guanyu Zhou, Junnan Li et al.
3 citations
Sensor Technology and Measurement Systems
1.05
article

Air Conditioning Load Monitoring in NILM Using Low Frequency Power Data

Minzhe Tian, Letian Guo, Guanyu Zhou, Junnan Li, Guohui Wang, Moran Ma
article en
3 citations

Abstract

Air conditioning loads are typically flexible loads and contribute significantly to enhancing energy efficiency while optimizing the operation of the electrical grid. However, air conditioners themselves are continuously variable loads, and accurately monitoring their load status is a challenging task in the field of non-intrusive load monitoring. To solve this problem, this paper proposes a template matching-based load monitoring method for air conditioners. First, this paper presents a load event detection strategy designed to identify changes in appliance operational status; subsequently, for each load event, multidimensional load features are extracted; finally, the extracted load features are fused, and in this way, an air conditioning load recognition model is constructed and trained to realize the air conditioning load state recognition. Tests comparing the proposed method with existing ones, using both the REDD dataset and real-world data collected in Henan, China, demonstrate that the proposed method can accurately monitor the air conditioning load status.

Tianjin University (CN), State Grid Corporation of China (China) (CN), Shanghai Electric (China) (CN)
State Grid Henan Electric Power Company
Affordable and clean energy
Openalex Percentile: Top 20%
Sensor Technology and Measurement Systems
1.05
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Air Conditioning Load Monitoring in NILM Using Low Frequency Power Data — Minzhe Tian, Letian Guo, et al. · (2024) | TGRS Research Map | TGRS