Flexible Grounding Line Selection Based on Power Variation

Aiming at the difficulty of flexible grounding line selection, a fault line selection method based on the phase change characteristics of zero sequence power is proposed. Based on the equivalent circuit of single-phase grounding fault in flexible grounding system, the difference characteristics of zero-sequence active power between intact line and fault line before and after neutral point parallel connection with small resistance are analyzed. It is found that there are significant differences between the waveforms of low-frequency reactive components of intact lines and faulty lines. The difference of steady-state zero-sequence active power between lines is compared by Hausdorff distance algorithm, and the implementation scheme of fault line selection is designed through the fault line selection criterion of Hausdorff distance parameters. The correctness and effectiveness of the proposed line selection scheme are verified by the calculation and analysis of Matlab simulation and experimental waveform records.

Authors

Institutions

Publication Details

Published
2024-10-25
DOI
https://doi.org/10.1109/icsgsc62639.2024.10813834
Primary Topic
Antenna Design and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Flexible Grounding Line Selection Based on Power Variation

Xinan Sheng, H. Jia, Mingjun Liu, Xiaojun Liu et al.
Antenna Design and Optimization
article

Flexible Grounding Line Selection Based on Power Variation

Xinan Sheng, H. Jia, Mingjun Liu, Xiaojun Liu, Sun Li-gong, H.W. Jiang
article en

Abstract

Aiming at the difficulty of flexible grounding line selection, a fault line selection method based on the phase change characteristics of zero sequence power is proposed. Based on the equivalent circuit of single-phase grounding fault in flexible grounding system, the difference characteristics of zero-sequence active power between intact line and fault line before and after neutral point parallel connection with small resistance are analyzed. It is found that there are significant differences between the waveforms of low-frequency reactive components of intact lines and faulty lines. The difference of steady-state zero-sequence active power between lines is compared by Hausdorff distance algorithm, and the implementation scheme of fault line selection is designed through the fault line selection criterion of Hausdorff distance parameters. The correctness and effectiveness of the proposed line selection scheme are verified by the calculation and analysis of Matlab simulation and experimental waveform records.

Northeast Electric Power University (CN), Jilin Electric Power Research Institute (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 58%
Antenna Design and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.