Pilot Protection Based on Hamming Distance for Transmission Line Connected to Renewable Energy Station

Affected by the converter control strategy, the fault characteristics of the renewable energy power supply are essentially distinctive from the traditional synchronous power supply, resulting in the deterioration of the traditional protection device action performance and the risk of rejection. In response to the above issues, the paper studies the fault current waveform difference between the renewable energy power supply and the traditional synchronous power supply, uses the Hamming distance to measure the current waveform difference, and proposes protection principle based on Hamming distance. The simulation results and fault recording data indicate that the Hamming distance can accurately distinguish the faults in and out of the zone in various fault scenarios, has good resistance to transition resistance and system noise, and can be applied to scenarios with weak output of renewable energy.

Authors

Institutions

Publication Details

Published
2024-10-25
DOI
https://doi.org/10.1109/icsgsc62639.2024.10813855
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pilot Protection Based on Hamming Distance for Transmission Line Connected to Renewable Energy Station

Lei Bao, Haiqing Huang, Pengfei Jin, Yan Liu et al.
Power Systems Fault Detection
article

Pilot Protection Based on Hamming Distance for Transmission Line Connected to Renewable Energy Station

Lei Bao, Haiqing Huang, Pengfei Jin, Yan Liu, Weitao Li
article en

Abstract

Affected by the converter control strategy, the fault characteristics of the renewable energy power supply are essentially distinctive from the traditional synchronous power supply, resulting in the deterioration of the traditional protection device action performance and the risk of rejection. In response to the above issues, the paper studies the fault current waveform difference between the renewable energy power supply and the traditional synchronous power supply, uses the Hamming distance to measure the current waveform difference, and proposes protection principle based on Hamming distance. The simulation results and fault recording data indicate that the Hamming distance can accurately distinguish the faults in and out of the zone in various fault scenarios, has good resistance to transition resistance and system noise, and can be applied to scenarios with weak output of renewable energy.

North China Electric Power University (CN), State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources
Affordable and clean energy
Openalex Percentile: Top 70%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Pilot Protection Based on Hamming Distance for Transmission Line Connected to Renewable Energy Station — Lei Bao, Haiqing Huang, et al. · (2024) | TGRS Research Map | TGRS