Multi-terminal Differential Protection Based on Composite Criterion for T-connected Distribution Network with Inverter Interfaced Distributed Generator

The access of inverter interfaced distributed generator (IIDG) challenges the protection configuration of traditional distribution network. In this paper, a composite criterion of multi-terminal differential protection for T-connected distribution networks is proposed. Firstly, the impact of IIDG on relay protection of distribution network is analyzed, and the problems of two differential protection criteria with IIDG integration are studied. Then, based on the control strategy and output characteristics of IIDG, a multi-terminal current differential protection with composite criterion applicable to IIDG accessing distribution network is proposed. Finally, the T-connected distribution network model of IIDG is constructed in the simulation software, and the action characteristics of the newly proposed multi-terminal differential protection based on composite criterion is simulated and analyzed under different fault types and fault locations.

Authors

Institutions

Publication Details

Published
2024-10-25
DOI
https://doi.org/10.1109/icsgsc62639.2024.10813683
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multi-terminal Differential Protection Based on Composite Criterion for T-connected Distribution Network with Inverter Interfaced Distributed Generator

Zhihan Yang, Jiangang Lü, Qiao Li, Wang Feng et al.
Power Systems Fault Detection
article

Multi-terminal Differential Protection Based on Composite Criterion for T-connected Distribution Network with Inverter Interfaced Distributed Generator

Zhihan Yang, Jiangang Lü, Qiao Li, Wang Feng, Yanjun Wen, Jia Zhu, L. Huang, Wei Liu
article en

Abstract

The access of inverter interfaced distributed generator (IIDG) challenges the protection configuration of traditional distribution network. In this paper, a composite criterion of multi-terminal differential protection for T-connected distribution networks is proposed. Firstly, the impact of IIDG on relay protection of distribution network is analyzed, and the problems of two differential protection criteria with IIDG integration are studied. Then, based on the control strategy and output characteristics of IIDG, a multi-terminal current differential protection with composite criterion applicable to IIDG accessing distribution network is proposed. Finally, the T-connected distribution network model of IIDG is constructed in the simulation software, and the action characteristics of the newly proposed multi-terminal differential protection based on composite criterion is simulated and analyzed under different fault types and fault locations.

China Southern Power Grid (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 70%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Multi-terminal Differential Protection Based on Composite Criterion for T-connected Distribution Network with Inverter Interfaced Distributed Generator — Zhihan Yang, Jiangang Lü, et al. · (2024) | TGRS Research Map | TGRS