Study on the Impact of SVG Active Harmonic Elimination on Inverter Side of LCC

The SVG is a commonly used reactive power compensation device in LCC converter stations to enhance the system's ability to withstand commutation failures. Although the SVG has advantages such as fast response and minimal impact from bus voltage drops, the harmonics generated by the SVG itself can affect the effectiveness of the converter transformer's filtering of the 5th and 7th harmonics. This paper analyzes the principle that the converter transformer's filtering of the 5th and 7th harmonics, and then take the impact of SVG on grid-side harmonics when performing functions such as reactive power compensation or characteristic subharmonic filtering into account, and finally, builds a simulation model in SIMULINK to verify the accuracy of the analysis.

Authors

Institutions

Publication Details

Published
2024-10-25
DOI
https://doi.org/10.1109/icsgsc62639.2024.10813642
Primary Topic
Power Systems and Renewable Energy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on the Impact of SVG Active Harmonic Elimination on Inverter Side of LCC

Yitao Liu, Jiabin Su, Bin Chen, Jin Chen et al.
Power Systems and Renewable Energy
article

Study on the Impact of SVG Active Harmonic Elimination on Inverter Side of LCC

Yitao Liu, Jiabin Su, Bin Chen, Jin Chen, Xiwen Hu
article en

Abstract

The SVG is a commonly used reactive power compensation device in LCC converter stations to enhance the system's ability to withstand commutation failures. Although the SVG has advantages such as fast response and minimal impact from bus voltage drops, the harmonics generated by the SVG itself can affect the effectiveness of the converter transformer's filtering of the 5th and 7th harmonics. This paper analyzes the principle that the converter transformer's filtering of the 5th and 7th harmonics, and then take the impact of SVG on grid-side harmonics when performing functions such as reactive power compensation or characteristic subharmonic filtering into account, and finally, builds a simulation model in SIMULINK to verify the accuracy of the analysis.

Nanjing Institute of Technology (CN), China Design Group (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 74%
Power Systems and Renewable Energy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.