A Design Method of DC-link Capacitor for Three-Phase SPWM Rectifier Under Asymmetric Grid Faults

The instantaneous active power and DC-link voltage of three-phase SPWM rectifiers can have the components of double fundamental frequency under asymmetric grid faults, affecting the system reliability and power quality. Firstly, the instantaneous active power characteristics of three-phase SPWM rectifiers both on the AC and DC sides are analyzed quantitatively, and the expression of double fundamental frequency component of the DC-link voltage is derived. Next, the most common asymmetric grid fault, single phase-to-ground fault, is considered through introducing a voltage drop coefficient. Then, the influence of single-phase voltage drop coefficient on the DC-link capacitor is analyzed. And the limit value of the DC-link capacitance is obtained, meanwhile considering the third harmonic constraint of the grid current. Finally, the simulation verifications are carried out, and the results have proven the correctness of the theoretical analysis in the paper.

Authors

Institutions

Publication Details

Published
2024-10-25
DOI
https://doi.org/10.1109/icsgsc62639.2024.10813672
Citations
2
Primary Topic
Quantum-Dot Cellular Automata
Type
article
Field-Weighted Citation Impact
0.72
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Design Method of DC-link Capacitor for Three-Phase SPWM Rectifier Under Asymmetric Grid Faults

Hong Cao, Yong Shi, Shuo Gao, Jiaqi Liu et al.
2 citations
Quantum-Dot Cellular Automata
0.72
article

A Design Method of DC-link Capacitor for Three-Phase SPWM Rectifier Under Asymmetric Grid Faults

Hong Cao, Yong Shi, Shuo Gao, Jiaqi Liu, Bao Xie
article en
2 citations

Abstract

The instantaneous active power and DC-link voltage of three-phase SPWM rectifiers can have the components of double fundamental frequency under asymmetric grid faults, affecting the system reliability and power quality. Firstly, the instantaneous active power characteristics of three-phase SPWM rectifiers both on the AC and DC sides are analyzed quantitatively, and the expression of double fundamental frequency component of the DC-link voltage is derived. Next, the most common asymmetric grid fault, single phase-to-ground fault, is considered through introducing a voltage drop coefficient. Then, the influence of single-phase voltage drop coefficient on the DC-link capacitor is analyzed. And the limit value of the DC-link capacitance is obtained, meanwhile considering the third harmonic constraint of the grid current. Finally, the simulation verifications are carried out, and the results have proven the correctness of the theoretical analysis in the paper.

North China Electric Power University (CN), Hefei University of Technology (CN), China Electric Power Research Institute
Climate action
Openalex Percentile: Top 24%
Quantum-Dot Cellular Automata
0.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.