An Ultrasound-Based Non-Invasive Blood Pressure Estimation Method Based on Optimal Vascular Wall Tracking Position

This study presents, for the first time, an ultrasound method combining focused and single plane wave transmissions to achieve single calibration, non-invasive, cuffless blood pressure monitoring. High-quality echo signals obtained from focused transmissions were first used to identify the optimal segment of the radial artery wall. Then, single plane wave signals were utilized to track this segment frame-by-frame and calculate local pulse wave velocity (PWV). Finally, the M-K equation was applied to estimate systolic and diastolic blood pressures. To validate the effectiveness of the proposed algorithm, 25 volunteers participated in the study. Data were collected using both an oscillometric cuff-based blood pressure monitor and our ultrasound system in four states: morning, evening, pre-exercise, and post-exercise. A total of 300 sets of comparative data were obtained. The overall mean deviation for systolic blood pressure was <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$2.2~\pm ~2.1$ </tex-math></inline-formula> mmHg, and for diastolic blood pressure, it was <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$2.1~\pm ~2.2$ </tex-math></inline-formula> mmHg. To our knowledge, this is the first study to achieve real-time blood pressure calculation within seconds using a single-array ultrasound transducer. Compared to existing non-invasive continuous blood pressure monitoring methods, this approach is faster and provides more accurate vascular wall information. Significance: Combined with affordable hardware, this method holds significant potential for the development of wearable devices for real-time cardiovascular health monitoring.

Authors

Institutions

Publication Details

Journal
IEEE Access
Published
2024-12-31
DOI
https://doi.org/10.1109/access.2024.3524614
Citations
2
Primary Topic
Ultrasound and Hyperthermia Applications
Type
article
Field-Weighted Citation Impact
0.37
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Ultrasound-Based Non-Invasive Blood Pressure Estimation Method Based on Optimal Vascular Wall Tracking Position

Liyuan Liu, Zhaoying Zheng, Xingguang Geng, Yitao Zhang et al.
2 citations
IEEE Access
Ultrasound and Hyperthermia Applications
0.37
article

An Ultrasound-Based Non-Invasive Blood Pressure Estimation Method Based on Optimal Vascular Wall Tracking Position

Liyuan Liu, Zhaoying Zheng, Xingguang Geng, Yitao Zhang, Fei Yao, Yunfeng Wang, Haiying Zhang
article en
2 citations

Abstract

This study presents, for the first time, an ultrasound method combining focused and single plane wave transmissions to achieve single calibration, non-invasive, cuffless blood pressure monitoring. High-quality echo signals obtained from focused transmissions were first used to identify the optimal segment of the radial artery wall. Then, single plane wave signals were utilized to track this segment frame-by-frame and calculate local pulse wave velocity (PWV). Finally, the M-K equation was applied to estimate systolic and diastolic blood pressures. To validate the effectiveness of the proposed algorithm, 25 volunteers participated in the study. Data were collected using both an oscillometric cuff-based blood pressure monitor and our ultrasound system in four states: morning, evening, pre-exercise, and post-exercise. A total of 300 sets of comparative data were obtained. The overall mean deviation for systolic blood pressure was <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$2.2~\pm ~2.1$ </tex-math></inline-formula> mmHg, and for diastolic blood pressure, it was <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$2.1~\pm ~2.2$ </tex-math></inline-formula> mmHg. To our knowledge, this is the first study to achieve real-time blood pressure calculation within seconds using a single-array ultrasound transducer. Compared to existing non-invasive continuous blood pressure monitoring methods, this approach is faster and provides more accurate vascular wall information. Significance: Combined with affordable hardware, this method holds significant potential for the development of wearable devices for real-time cardiovascular health monitoring.

IEEE AccessVol. 13
Chinese Academy of Sciences (CN), Chinese Academy of Medical Sciences & Peking Union Medical College (CN), Institute of Microelectronics (CN)
Zero hunger
Openalex Percentile: Top 41%
Ultrasound and Hyperthermia Applications
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.