An Efficient Communication Protocol for Real-Time Body Sensor Data Acquisition and Feedback in Interactive Wearable Systems

We introduce a novel wired communication approach for interactive wearable systems, employing a single signal wire and innovative group addressing protocol to reduce overhead. While wireless solutions dominate body sensor networks, wired approaches offer advantages for interactive applications that require low latency, high reliability, and communication with high-density nodes; yet they have been less explored in the context of wearable systems. Many commercial products use wired connections without disclosing technical details, limiting broader adoption. To address this gap, we present and test a new group addressing protocol implemented using Universal Asynchronous Receiver–Transmitter (UART) hardware, disclosing frame diagrams and node architectures. We developed a prototype interactive jacket with nine sensor/actuator nodes connected via three wires for power supply and data transmission to a wireless gateway. Mathematical analysis showed an overhead reduction of approximately 50% compared to traditional individual addressing. Our solution is the most wire-efficient among wired interactive wearable systems reviewed in the literature, using only one signal wire; other methods require at least two wires and often have overlapping topologies. Performance experimental evaluation revealed a total feedback delay of 2.27 ms and a maximum data frame rate of 435.4 Hz, comparable to the best-performing products and leaving room for twice the performance calculated theoretically. These results indicate that the proposed approach is suitable for interactive wearable systems, both for real-time applications and high-resolution data acquisition.

Authors

Institutions

Publication Details

Journal
Journal of Sensor and Actuator Networks
Published
2024-12-30
DOI
https://doi.org/10.3390/jsan14010004
Citations
3
Primary Topic
Wireless Body Area Networks
Type
article
Field-Weighted Citation Impact
0.55
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Efficient Communication Protocol for Real-Time Body Sensor Data Acquisition and Feedback in Interactive Wearable Systems

Armands Ancāns, Modris Greitāns, Sandis Kagis
3 citations
Journal of Sensor and Actuator Networks
Wireless Body Area Networks
0.55
article

An Efficient Communication Protocol for Real-Time Body Sensor Data Acquisition and Feedback in Interactive Wearable Systems

Armands Ancāns, Modris Greitāns, Sandis Kagis
article en
3 citations

Abstract

We introduce a novel wired communication approach for interactive wearable systems, employing a single signal wire and innovative group addressing protocol to reduce overhead. While wireless solutions dominate body sensor networks, wired approaches offer advantages for interactive applications that require low latency, high reliability, and communication with high-density nodes; yet they have been less explored in the context of wearable systems. Many commercial products use wired connections without disclosing technical details, limiting broader adoption. To address this gap, we present and test a new group addressing protocol implemented using Universal Asynchronous Receiver–Transmitter (UART) hardware, disclosing frame diagrams and node architectures. We developed a prototype interactive jacket with nine sensor/actuator nodes connected via three wires for power supply and data transmission to a wireless gateway. Mathematical analysis showed an overhead reduction of approximately 50% compared to traditional individual addressing. Our solution is the most wire-efficient among wired interactive wearable systems reviewed in the literature, using only one signal wire; other methods require at least two wires and often have overlapping topologies. Performance experimental evaluation revealed a total feedback delay of 2.27 ms and a maximum data frame rate of 435.4 Hz, comparable to the best-performing products and leaving room for twice the performance calculated theoretically. These results indicate that the proposed approach is suitable for interactive wearable systems, both for real-time applications and high-resolution data acquisition.

Journal of Sensor and Actuator NetworksVol. 14(1)
Institute of Electronics and Computer Science (LV)
Openalex Percentile: Top 35%
Wireless Body Area Networks
0.55
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

An Efficient Communication Protocol for Real-Time Body Sensor Data Acquisition and Feedback in Interactive Wearable Systems — Armands Ancāns, Modris Greitāns, et al. · Journal of Sensor and Actuator Networks (2024) | TGRS Research Map | TGRS