High-resolution hemodynamic estimation from ultrafast ultrasound image velocimetry using a physics-informed neural network

<i>Objective.</i>Estimating the high-resolution (HR) blood flow velocity and pressure fields for the diagnosis and treatment of vascular diseases remains challenging.<i>Approach</i>. In this study, a physics-informed neural network (PINN) with a refined mapping capability was combined with ultrafast ultrasound image velocimetry (u-UIV) to predict HR hemodynamic parameters. Specifically, the Navier-Stokes equations were encoded into the PINN to dynamically optimize the network performance under physical constraints, and a refined mapping network was added at the input to achieve data refinement. During the prediction of HR ultrasound hemodynamic parameters, only the sparse spatial coordinates in the time series were input into the PINN, and the velocity vectors generated from the u-UIV were used together with physical residuals to enhance the physical correctness of HR predictions during the iterative process.<i>Main results.</i>The performance of the refined mapping network was validated via simulations, with a 1.9-fold increase in the radial resolution and a 2.5-fold increase in the axial resolution. HR velocity field estimation from<i>in vitro</i>and<i>in vivo</i>data showed good agreement with theoretical values and u-UIV measurements, with micrometer-level spatial resolution (88<i>µ</i>m×115<i>µ</i>m for straight vessel, 75<i>µ</i>m×120<i>µ</i>m for stenotic vessel and 63<i>µ</i>m × 79<i>µ</i>m for<i>in vivo</i>data), while the pressure field could be inferred from physical laws.<i>Significance.</i>The proposed method performs well when few data samples are available and has the potential to assist in the clinical diagnosis of vascular diseases.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2024-12-30
DOI
https://doi.org/10.1088/1361-6560/ada418
Citations
4
Primary Topic
Flow Measurement and Analysis
Type
article
Field-Weighted Citation Impact
1.08

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-resolution hemodynamic estimation from ultrafast ultrasound image velocimetry using a physics-informed neural network

Hanbing Chu, Liyuan Jiang, Mingting Zhu, Mingxi Wan et al.
4 citations
Physics in Medicine and Biology
Flow Measurement and Analysis
1.08
article

High-resolution hemodynamic estimation from ultrafast ultrasound image velocimetry using a physics-informed neural network

Hanbing Chu, Liyuan Jiang, Mingting Zhu, Mingxi Wan, Yujin Zong, Hao Wang, Jiacheng Liu, Meiling Liang
article en
4 citations

Abstract

<i>Objective.</i>Estimating the high-resolution (HR) blood flow velocity and pressure fields for the diagnosis and treatment of vascular diseases remains challenging.<i>Approach</i>. In this study, a physics-informed neural network (PINN) with a refined mapping capability was combined with ultrafast ultrasound image velocimetry (u-UIV) to predict HR hemodynamic parameters. Specifically, the Navier-Stokes equations were encoded into the PINN to dynamically optimize the network performance under physical constraints, and a refined mapping network was added at the input to achieve data refinement. During the prediction of HR ultrasound hemodynamic parameters, only the sparse spatial coordinates in the time series were input into the PINN, and the velocity vectors generated from the u-UIV were used together with physical residuals to enhance the physical correctness of HR predictions during the iterative process.<i>Main results.</i>The performance of the refined mapping network was validated via simulations, with a 1.9-fold increase in the radial resolution and a 2.5-fold increase in the axial resolution. HR velocity field estimation from<i>in vitro</i>and<i>in vivo</i>data showed good agreement with theoretical values and u-UIV measurements, with micrometer-level spatial resolution (88<i>µ</i>m×115<i>µ</i>m for straight vessel, 75<i>µ</i>m×120<i>µ</i>m for stenotic vessel and 63<i>µ</i>m × 79<i>µ</i>m for<i>in vivo</i>data), while the pressure field could be inferred from physical laws.<i>Significance.</i>The proposed method performs well when few data samples are available and has the potential to assist in the clinical diagnosis of vascular diseases.

Physics in Medicine and BiologyVol. 70(2)
Xi'an Jiaotong University (CN)
National Natural Science Foundation of China
Good health and well-being
Openalex Percentile: Top 26%
Flow Measurement and Analysis
1.08
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.