Section Locating of Water-tree Degraded Cable by Measuring Residual Charges Induced by Induced Voltage Pulses

To establish a novel section locating technique for a water-tree degraded 22 kV cross-linked polyethylene (XLPE) cable that is included in another undegraded cables, we measured a reflected injection pulse at the impedance mismatch which is dependent on water trees. The injection pulse was propagated into cables to be measured, and the measured arrival times of reflected pulses containing residual charges due to water trees were varied depending on the locations of water-tree degraded cables. The section locating was achieved by using arrival time of the reflected pulse.

Authors

Institutions

Publication Details

Journal
IEEJ Transactions on Fundamentals and Materials
Published
2024-12-31
DOI
https://doi.org/10.1541/ieejfms.145.23
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Section Locating of Water-tree Degraded Cable by Measuring Residual Charges Induced by Induced Voltage Pulses

Koki Watanabe, Kazunori Miyazaki, Tatsuya Sakoda, Nobuaki Negishi et al.
IEEJ Transactions on Fundamentals and Materials
Power Systems Fault Detection
article

Section Locating of Water-tree Degraded Cable by Measuring Residual Charges Induced by Induced Voltage Pulses

Koki Watanabe, Kazunori Miyazaki, Tatsuya Sakoda, Nobuaki Negishi, Akira Takahashi
article en

Abstract

To establish a novel section locating technique for a water-tree degraded 22 kV cross-linked polyethylene (XLPE) cable that is included in another undegraded cables, we measured a reflected injection pulse at the impedance mismatch which is dependent on water trees. The injection pulse was propagated into cables to be measured, and the measured arrival times of reflected pulses containing residual charges due to water trees were varied depending on the locations of water-tree degraded cables. The section locating was achieved by using arrival time of the reflected pulse.

IEEJ Transactions on Fundamentals and MaterialsVol. 145(1)
University of Miyazaki (JP), TEPCO (Japan) (JP)
Clean water and sanitation
Openalex Percentile: Top 70%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Section Locating of Water-tree Degraded Cable by Measuring Residual Charges Induced by Induced Voltage Pulses — Koki Watanabe, Kazunori Miyazaki, et al. · IEEJ Transactions on Fundamentals and Materials (2024) | TGRS Research Map | TGRS