EQUILIBRIUM MOISTURE CONTENT AND MECHANICAL PERFORMANCE OF WOOD AFTER HEATING AND COOLING ASSUMING CONTINUED USE AFTER A FIRE

In order to continue using the load-bearing parts of wooden structural members after a fire, it is necessary to understand their mechanical performance after exposure to fire. Equilibrium moisture content, Young’s modulus, and bending strength were measured on sugi specimens that were once exposed to elevated temperatures of 60-210°C. Results revealed that Young’s modulus and bending strength increased with temperature history of up to 150°C, presumably due to a decrease in equilibrium moisture content. The heating times were 30 minutes and 8 hours, and above 180°C, the longer the heating time, the greater the decline in mechanical performance.

Authors

Institutions

Publication Details

Journal
Journal of Structural and Construction Engineering (Transactions of AIJ)
Published
2024-12-31
DOI
https://doi.org/10.3130/aijs.90.113
Primary Topic
Fire dynamics and safety research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

EQUILIBRIUM MOISTURE CONTENT AND MECHANICAL PERFORMANCE OF WOOD AFTER HEATING AND COOLING ASSUMING CONTINUED USE AFTER A FIRE

Tomoyo HOKIBARA, Ryo TAKASE, Shohei Yamashita, Tatsuro Suzuki
Journal of Structural and Construction Engineering (Transactions of AIJ)
Fire dynamics and safety research
article

EQUILIBRIUM MOISTURE CONTENT AND MECHANICAL PERFORMANCE OF WOOD AFTER HEATING AND COOLING ASSUMING CONTINUED USE AFTER A FIRE

Tomoyo HOKIBARA, Ryo TAKASE, Shohei Yamashita, Tatsuro Suzuki
article en

Abstract

In order to continue using the load-bearing parts of wooden structural members after a fire, it is necessary to understand their mechanical performance after exposure to fire. Equilibrium moisture content, Young’s modulus, and bending strength were measured on sugi specimens that were once exposed to elevated temperatures of 60-210°C. Results revealed that Young’s modulus and bending strength increased with temperature history of up to 150°C, presumably due to a decrease in equilibrium moisture content. The heating times were 30 minutes and 8 hours, and above 180°C, the longer the heating time, the greater the decline in mechanical performance.

Journal of Structural and Construction Engineering (Transactions of AIJ)Vol. 90(827)
Waseda University (JP)
Openalex Percentile: Top 70%
Fire dynamics and safety research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.