Development of miniaturized autonomous and versatile gas chromatograph for Volatile Organic Compounds monitoring using Nano-Gravimetric-Detector

• Proof of concept of miniaturized gas chromatograph. • First coupling of preconcentrator to Nano Gravimetric Detector. • Monitoring and long-survey of air quality pollutants using autonomous system. • Volatile Organic Compounds monitoring in extreme environments. Environmental monitoring and air quality survey during long-term field campaign tests, especially in low-accessibility or extreme environments, requires robust, standalone and autonomous analyzer with low gas consumption and minimal human intervention. The current states of art emphasize the need to develop miniaturized GC based on novel detectors that offers the best compromise between carrier gas consumption, detection limits and panel of measured VOCs. This work presents the development and optimization of MAVERIC, a miniaturized and autonomous Gas Chromatograph system coupled to an innovative Nano Gravimetric Detector ( NGD) based on NEMS (nano-electromechanical-system) resonator. A homemade software is developed to control the instrument as well as the electronics modules. The system operates at low flow rate (2 mL.min −1 ) of helium used as carrier gas, and allows the measurements of VOCs from C 6 to C 10 in less than 30 min. A mixture of isoprene, benzene, toluene and α-pinene is used to optimize experimental conditions. Under optimal conditions, the detection limit, the stability, the repeatability and the linearity of the analytical system are assessed. A detection limit of sub-ppb to few ppt level was determined for C 6 and C 9 compounds, respectively. The lowest detection limit corresponds to the highest molecular weight compounds due to NGD sensitivity at ambient temperature. The system is standalone, portable, robust and equipped with 4G connection that allows remote control of the instrument and easy data export. It is very adapted for a long period field campaign test, environmental monitoring and air quality survey outdoors and in low-accessibility or extreme environments.

Authors

Institutions

Publication Details

Journal
Journal of Chromatography Open
Published
2024-12-31
DOI
https://doi.org/10.1016/j.jcoa.2024.100202
Primary Topic
Analytical Chemistry and Chromatography
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of miniaturized autonomous and versatile gas chromatograph for Volatile Organic Compounds monitoring using Nano-Gravimetric-Detector

François Ravetta, Éric Colinet, Anaïs Féron, Cyril Szopa et al.
Journal of Chromatography Open
Analytical Chemistry and Chromatography
article

Development of miniaturized autonomous and versatile gas chromatograph for Volatile Organic Compounds monitoring using Nano-Gravimetric-Detector

François Ravetta, Éric Colinet, Anaïs Féron, Cyril Szopa, Fabrice Bertrand, Patrice Coll, Agnès Borbon, Malak Rizk-Bigourd, Cécile Gaimoz, Vincent Guerreni, Vivien Tranier, Jean-Pierre Pineau, David Coscia, M. Cabane
article en

Abstract

• Proof of concept of miniaturized gas chromatograph. • First coupling of preconcentrator to Nano Gravimetric Detector. • Monitoring and long-survey of air quality pollutants using autonomous system. • Volatile Organic Compounds monitoring in extreme environments. Environmental monitoring and air quality survey during long-term field campaign tests, especially in low-accessibility or extreme environments, requires robust, standalone and autonomous analyzer with low gas consumption and minimal human intervention. The current states of art emphasize the need to develop miniaturized GC based on novel detectors that offers the best compromise between carrier gas consumption, detection limits and panel of measured VOCs. This work presents the development and optimization of MAVERIC, a miniaturized and autonomous Gas Chromatograph system coupled to an innovative Nano Gravimetric Detector ( NGD) based on NEMS (nano-electromechanical-system) resonator. A homemade software is developed to control the instrument as well as the electronics modules. The system operates at low flow rate (2 mL.min −1 ) of helium used as carrier gas, and allows the measurements of VOCs from C 6 to C 10 in less than 30 min. A mixture of isoprene, benzene, toluene and α-pinene is used to optimize experimental conditions. Under optimal conditions, the detection limit, the stability, the repeatability and the linearity of the analytical system are assessed. A detection limit of sub-ppb to few ppt level was determined for C 6 and C 9 compounds, respectively. The lowest detection limit corresponds to the highest molecular weight compounds due to NGD sensitivity at ambient temperature. The system is standalone, portable, robust and equipped with 4G connection that allows remote control of the instrument and easy data export. It is very adapted for a long period field campaign test, environmental monitoring and air quality survey outdoors and in low-accessibility or extreme environments.

Journal of Chromatography OpenVol. 7
Centre National de la Recherche Scientifique (FR), Université de Versailles Saint-Quentin-en-Yvelines (FR), Université Paris-Est Créteil (FR), Université Clermont Auvergne (FR), Université Paris Cité (FR), Université Paris-Saclay (FR), Paris-Est Sup (FR), Sorbonne Université (FR), Atmosphere Systems and Services (FR), LVMH (France) (FR), Institut Pierre-Simon Laplace (FR), Laboratoire de Météorologie Physique (FR), Laboratoire Interuniversitaire des Systèmes Atmosphériques (FR), Institut de Microélectronique, Electromagnétisme et Photonique (FR), Laboratoire atmosphères, milieux, observations spatiales (FR), Laboratoire Techniques, Territoires et Sociétés (FR), Lieux, Identités, eSpaces, Activités
Centre National de la Recherche Scientifique
Openalex Percentile: Top 81%
Analytical Chemistry and Chromatography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.