Evaluating Human Factors in TFM Sizing Accuracy: Statistical Findings from a Round-Robin Programme (Part 2)

This paper reports on the results of the second part of a round-robin programme designed to assess the accuracy of TFM (Total Focussing Method) sizing as it relates to probability of detection truth values. Part 1 of the programme involved analysis of flaw responses simulated using the FMC (Full Matrix Capture) method of acquisition in CIVA simulation software. The report [1] noted that the mean standard deviation of height-sizing error for all participants 0.56mm and the mean standard deviation of error for ligament sizing was 0.88mm. CIVA simulation software is well known for its ability to reproduce ultrasonic results; however, software simulation cannot fully represent the human factors of uncertainty. To address the human factors, a second part to the programme was organised whereby welds with seeded flaws were provided to volunteers from several labs. Their task was to scan the welds using an acquisition format compatible with a TFM algorithm and analyse the data using the TFM algorithm of their choice. Height, length and smallest ligament was to be reported. This report summarises the statistical findings of Part 2 of the programme.

Authors

Publication Details

Journal
e-Journal of Nondestructive Testing
Published
2024-12-30
DOI
https://doi.org/10.58286/30605
Primary Topic
Reliability and Maintenance Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating Human Factors in TFM Sizing Accuracy: Statistical Findings from a Round-Robin Programme (Part 2)

Mariana Burrowes, Cesar Giron Camerini, Edward Ginzel, Gabriela Ribeiro Pereira
e-Journal of Nondestructive Testing
Reliability and Maintenance Optimization
article

Evaluating Human Factors in TFM Sizing Accuracy: Statistical Findings from a Round-Robin Programme (Part 2)

Mariana Burrowes, Cesar Giron Camerini, Edward Ginzel, Gabriela Ribeiro Pereira
article en

Abstract

This paper reports on the results of the second part of a round-robin programme designed to assess the accuracy of TFM (Total Focussing Method) sizing as it relates to probability of detection truth values. Part 1 of the programme involved analysis of flaw responses simulated using the FMC (Full Matrix Capture) method of acquisition in CIVA simulation software. The report [1] noted that the mean standard deviation of height-sizing error for all participants 0.56mm and the mean standard deviation of error for ligament sizing was 0.88mm. CIVA simulation software is well known for its ability to reproduce ultrasonic results; however, software simulation cannot fully represent the human factors of uncertainty. To address the human factors, a second part to the programme was organised whereby welds with seeded flaws were provided to volunteers from several labs. Their task was to scan the welds using an acquisition format compatible with a TFM algorithm and analyse the data using the TFM algorithm of their choice. Height, length and smallest ligament was to be reported. This report summarises the statistical findings of Part 2 of the programme.

e-Journal of Nondestructive TestingVol. 30(1)
Openalex Percentile: Top 70%
Reliability and Maintenance Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluating Human Factors in TFM Sizing Accuracy: Statistical Findings from a Round-Robin Programme (Part 2) — Mariana Burrowes, Cesar Giron Camerini, et al. · e-Journal of Nondestructive Testing (2024) | TGRS Research Map | TGRS